2001
DOI: 10.1021/es001126z
|View full text |Cite
|
Sign up to set email alerts
|

Platinum and Rhodium Concentrations in Airborne Particulate Matter in Germany from 1988 to 1998

Abstract: Increases in platinum group element (PGE) concentrations in ambient air and dust since the introduction of automotive catalytic converters in 1988 is a cause of concern. Until now, data derived from engine-test bench experiments have provided the basis for the assessment of human health risks associated with PGE exposure. Such experiments have provided valuable information regarding emission data that has been used to estimate ambient exposure concentrations. However, these data are not necessarily representat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
68
0
4

Year Published

2004
2004
2023
2023

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 128 publications
(74 citation statements)
references
References 27 publications
2
68
0
4
Order By: Relevance
“…The inhalation of these small particles is of special concern due to their uptake by alveolar cells. As an overall trend, it can be seen that PGM concentrations in airborne samples are clearly rising since the introduction of automobile catalytic converters, as demonstrated for the period 1988 -1998 in Germany Zereini et al 2001). Background levels of approximately 2 pg m À3 for Pt in Germany (Rosner and Merget 2000), and below 0.06 pg m À3 for Pd in California (Johnson et al 1976), were described prior to the introduction of catalysts.…”
Section: Pgm Emission From Catalytic Convertersmentioning
confidence: 97%
“…The inhalation of these small particles is of special concern due to their uptake by alveolar cells. As an overall trend, it can be seen that PGM concentrations in airborne samples are clearly rising since the introduction of automobile catalytic converters, as demonstrated for the period 1988 -1998 in Germany Zereini et al 2001). Background levels of approximately 2 pg m À3 for Pt in Germany (Rosner and Merget 2000), and below 0.06 pg m À3 for Pd in California (Johnson et al 1976), were described prior to the introduction of catalysts.…”
Section: Pgm Emission From Catalytic Convertersmentioning
confidence: 97%
“…In this context, halogenated platinum compounds have been identified as potent respiratory allergens leading to rhinitis, conjunctivitis, asthma and urticaria [1]. The toxicologically relevant components of DEP include PLGE [40, 41], but the role of the individual components was unclear. Our data suggest that the activity of PLGE on DC functions is specifically involved in the generation and amplification of the immune response to allergens.…”
Section: Discussionmentioning
confidence: 99%
“…Determination of platinum in atmospheric aerosols is particularly important in relation to human health because molecules of these metals can enter the human body via the respiratory tract (fraction <10 μm) (Dubiella-Jackowska et al 2007). The detection of total platinum concentrations in environmental matrices requires very sensitive and selective instrumental methods, such as instrumental neutron activation analysis (INAA) (Probst et al 2001), graphite furnace atomic absorption spectroscopy (GF-AAS), electrothermal atomic absorption spectrometry (ET-AAS) (Tilch et al 2000), cathodic stripping voltammetry (CSV) (Zereini et al 2001), inductively coupled plasma mass spectrometry (ICP-MS) (Farago et al 1998;Hann et al 2003;Köllensperger et al 2003;Curtis et al 2010), and inductively coupled plasma optical emission spectrometry (ICP-OES) (Orecchio and Amorello 2011;Van Wyk et al 2011. Objectives of methodological work concern sample pre-treatment procedures for preconcentration and selective and quantitative separation from interfering elements.…”
Section: Analysis Of Total Platinummentioning
confidence: 99%