Polarization-resolved second harmonic generation microscopy with a four-channel Stokes-polarimeter

Abstract: We developed a four-channel photon counting based Stokes-polarimeter for spatial characterization of polarization effects in second harmonic generation (SHG). We have implemented a calibration technique allowing quantitative measurement of polarization parameters, such as the degree of polarization (DOP), degree of linear polarization (DOLP), degree of circular polarization (DOCP), as well as anisotropy from the acquired Stokes parameters. The technique is used as contrast mechanism to characterize the polariz… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
58
0

Year Published

2013
2013
2023
2023

Publication Types

Select...
5
3
1

Relationship

2
7

Authors

Journals

citations
Cited by 60 publications
(60 citation statements)
references
References 39 publications
2
58
0
Order By: Relevance
“…The SHG signals from non-tumorous thyroid tissue and tumors differed significantly in their DOLP values, indicating that tumor tissue has a greater degree of ultrastructural collagen disorder. This conclusion is somewhat similar to a previous study of the DOLP of SHG from collagen type I gels formed from bovine tendon [19]. Generally, care must be taken in interpreting DOLP data, since the circular polarization component can alter the DOLP due to SHG radiation propagation through a birefringent sample.…”
Section: Discussionsupporting
confidence: 88%
“…The SHG signals from non-tumorous thyroid tissue and tumors differed significantly in their DOLP values, indicating that tumor tissue has a greater degree of ultrastructural collagen disorder. This conclusion is somewhat similar to a previous study of the DOLP of SHG from collagen type I gels formed from bovine tendon [19]. Generally, care must be taken in interpreting DOLP data, since the circular polarization component can alter the DOLP due to SHG radiation propagation through a birefringent sample.…”
Section: Discussionsupporting
confidence: 88%
“…Stokes vector based SHG microscopy resolves the polarization states of the SH signal and allows the deduction of the molecular organization of collagen, skeletal muscle, starch etc 111213…”
mentioning
confidence: 99%
“…The experimental arrangement of our SHG imaging system used to measure the polarization states of the SHG signal is described in detail in [20]. A femtosecond Ti:Sapphire (Coherent Mira Optima 900-F) laser oscillator was as the excitation light source.…”
Section: Polarization Imaging Systemmentioning
confidence: 99%
“…We used SH signal at 400 nm as a light source and was created by focusing the 800 nm laser beam into KDP micro-crystals (SIGMA, Germany) immersed in oil for optimal index matching and sandwiched between two cover glass slips. The SH light is collimated by the condenser lens in transmission mode then passed through the PSG as described in the Materials and Methods of our previous work [20] to generate 0°, 90°, 45° and RC polarization states. We have optimized our fourchannel Stokes-polarimeter at 400 nm by minimizing the propagation of relative errors on the intensities after multiplication by the instrument matrix (A 4x4 ) -1 .…”
Section: Calibrationmentioning
confidence: 99%