We developed a four-channel photon counting based Stokes-polarimeter for spatial characterization of polarization effects in second harmonic generation (SHG). We have implemented a calibration technique allowing quantitative measurement of polarization parameters, such as the degree of polarization (DOP), degree of linear polarization (DOLP), degree of circular polarization (DOCP), as well as anisotropy from the acquired Stokes parameters. The technique is used as contrast mechanism to characterize the polarization properties from two potassium dihydrogen phosphate (KDP) micro-crystals and collagen type-I in SHG microscopy.
Laser speckle contrast imaging is a technique used for imaging blood flow without scanning. Though several studies have attempted to combine spatial and temporal statistics of laser speckle images for reducing image noise as well as preserving acceptable spatiotemporal resolution, the statistical accuracy of these spatiotemporal methods has not been thoroughly compared. Through numerical simulation and animal experiments, this study investigates the changes in the mean speckle contrast values and the relative noise of the speckle contrast images computed by these methods with various numbers of frames and spatial windows. The simulation results show that the maximum relative error of the mean speckle contrast computed by the spatiotemporal laser speckle contrast analysis (STLASCA) method, in which the speckle contrast images are computed by analyzing the 3-D spatiotemporal speckle image cube, is approximately 5%, while it is higher than 13% for other methods. Changes in the mean speckle contrast values and the relative noise computed by these methods for animal experiment data are consistent with the simulation results. Our results demonstrate that STLASCA achieves more accurate speckle contrast, and suggest that STLASCA most effectively utilizes the number of pixels, thus achieving maximized speckle contrast, and thereby maximizing the variation of the laser speckle contrast image.
We report on the measurement and analysis of the polarization state of second harmonic signals generated by starch granules, using a four-channel photon counting based Stokes-polarimeter. Various polarization parameters, such as the degree of polarization (DOP), the degree of linear polarization (DOLP), the degree of circular polarization (DOCP), and anisotropy are extracted from the 2D second harmonic Stokes images of starch granules. The concentric shell structure of a starch granule forms a natural photonic crystal structure. By integration over all the solid angle, it will allow very similar SHG quantum efficiency regardless of the angle or the states of incident polarization. Given type I phase matching and the concentric shell structure of a starch granule, one can easily infer the polarization states of the input beam from the resulting SH micrograph.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.