2021
DOI: 10.18596/jotcsa.728165
|View full text |Cite
|
Sign up to set email alerts
|

Poly(glutamic acid) Modified Pencil Graphite Electrode for Voltammetric Determination of Bisphenol A

Abstract: Bisphenol A (BPA), which is an endocrine-disrupting substance, is often utilized as beverage and food packing material, and it may accumulate in nutrition and water sources, which is why it is important to monitor. In this study, for the determination of bisphenol A, electro-polymerization of glutamic acid (GA) was performed on a pencil graphite electrode (PGE). The performance of the sensor (PGA/PGE) for determining bisphenol A was examined utilizing the cyclic voltammetric (CV) and differential pulse voltamm… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 52 publications
0
4
0
Order By: Relevance
“…The oxidation peak current increased with the number of cycles, indicating the formation of a conductive polymer film on the ZnO NPs–CPE surface. According to the literature [ 36 , 48 ], the glutamic acid monomer is oxidized first at a higher positive potential to form α- amino free radicals, and these cation radicals can form carbon–nitrogen links at the carbon electrode surface, and then after the poly (glutamic acid) films are formed as described in Scheme 2 [ 36 , 48 ].
Fig.
…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The oxidation peak current increased with the number of cycles, indicating the formation of a conductive polymer film on the ZnO NPs–CPE surface. According to the literature [ 36 , 48 ], the glutamic acid monomer is oxidized first at a higher positive potential to form α- amino free radicals, and these cation radicals can form carbon–nitrogen links at the carbon electrode surface, and then after the poly (glutamic acid) films are formed as described in Scheme 2 [ 36 , 48 ].
Fig.
…”
Section: Resultsmentioning
confidence: 99%
“…1 B) is among the common amino acids that can easily be electropolymerized on the electrode surface to form poly (glutamic acid) [ 35 ]. Poly (glutamic acid) contains glutamate repeating units and free protonated carboxylic groups (pKa = 4.45) by linking α-amino and δ-carboxylic acid functional groups, which show enhanced properties in electrochemical applications [ 36 ]. Electrodes modified with poly (glutamic acid) have been successfully used in the determination of various analytes such as Epinephrine [ 37 ], Hydrazine [ 38 ], L-tryptophan [ 35 ], Bisphenol A [ 36 ], Rutin [ 39 ] and Gallic acid [ 40 ].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Pencil graphite is widely used in electrochemical determinations due to its low cost (27)(28)(29)(30)(31). There are usually two types: larger-diameter wood tips or finer-diameter mechanical tips.…”
Section: Introductionmentioning
confidence: 99%