2002
DOI: 10.1016/s0378-5173(02)00362-9
|View full text |Cite
|
Sign up to set email alerts
|

Polymer particle erosion controlling drug release. II. Swelling investigations to clarify the release mechanism

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
17
0

Year Published

2007
2007
2016
2016

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 46 publications
(18 citation statements)
references
References 25 publications
1
17
0
Order By: Relevance
“…The axial expansion could be again the result of discharge and relaxation of tablet compression forces imposed during tabletting and is in agreement with earlier studies, 13,22 even though some different findings were reported elsewhere.…”
Section: Core Changessupporting
confidence: 92%
“…The axial expansion could be again the result of discharge and relaxation of tablet compression forces imposed during tabletting and is in agreement with earlier studies, 13,22 even though some different findings were reported elsewhere.…”
Section: Core Changessupporting
confidence: 92%
“…The calculations were carried out in Excel. Several simplifying assumptions were made and used the calculations: constant BHT concentration in pipe material, constant temperature of 33 o C, measurements commenced after 14 hours into the experiment, which was the time required for the temperature to stabilise at 33 o C, constant flow velocity of 1m/s, time step equalled time required for one circulation cycle of water in the system (150 s), diffusive layer thickness derived from literature and equal to 100μm [23,24]. Calculations were conducted with the method of successive approximations, adjusting the diffusion coefficient values.…”
Section: Determination Of Diffusion Coefficient Value For Bhtmentioning
confidence: 99%
“…In addition, an increase of mass transfer rate and a decrease of film thickness as the increment of basket rotation speed has been reported (9). Although the erosion based on the low viscosity grade of the material was strongly influenced by agitation, the polymer particle erosion was only moderately affected by the hydrodynamic stress (14). Owing to the coating by layering both sides with strong gelling layer containing HPMC, the influence of hydrodynamic force on drug dissolution from the three-layer tablet was minimized.…”
Section: In Vitro Drug Release From the Prepared Tabletsmentioning
confidence: 95%