2022
DOI: 10.1049/pel2.12300
|View full text |Cite
|
Sign up to set email alerts
|

Post‐fault operation strategy for single open‐phase fault in three‐phase induction motor drives

Abstract: Single open-phase fault (SOPF) in three-phase induction motor (TPIM) drives leads to undesired performances and in some cases shutdown of the drive system. This research proposes a post-fault operation strategy based on direct rotor field-oriented control (RFOC) technique for wye-connected TPIM drives during SOPF. In the proposed control system, symmetrical and asymmetrical transformation matrices are utilized for stator voltage and current variables, respectively. In addition, an extended Kalman filter (EKF) … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 40 publications
0
4
0
Order By: Relevance
“…With all derivatives in the and eliminated, while setting equal to in the and equations. According to the previous assumptions the following matrix resulted [12,13].…”
Section: Induction Motor Modellingmentioning
confidence: 99%
See 1 more Smart Citation
“…With all derivatives in the and eliminated, while setting equal to in the and equations. According to the previous assumptions the following matrix resulted [12,13].…”
Section: Induction Motor Modellingmentioning
confidence: 99%
“…The system's 50-60 Hz component's static representation allowed for a significant reduction in the number of calculations needed. [11,12,13,16]. In this study, a dynamic simulation for a three-phase induction motor is these simulations are based on a reduced-order model equation.…”
Section: Introductionmentioning
confidence: 99%
“…Overcurrent was the basis for the proposed protection scheme. The single-phasing fault with different fault tolerant control (FTC) algorithms has been reviewed in [14][15][16][17][18][19][20][21]. In [14], the authors proposed a method based on a simple open-switch fault monitoring system that uses a reference voltage vector analysis in the stationary α-β coordinates for failure detection.…”
Section: Introductionmentioning
confidence: 99%
“…In [14], the authors proposed a method based on a simple open-switch fault monitoring system that uses a reference voltage vector analysis in the stationary α-β coordinates for failure detection. The authors in [15] proposed a post-fault control strategy for wye-connected three-phase induction motor drives during a single open-phase fault. The proposed direct rotor field-oriented control system is derived from the conventional vector control system with minor modifications.…”
Section: Introductionmentioning
confidence: 99%