2004
DOI: 10.1016/j.jelechem.2003.11.041
|View full text |Cite
|
Sign up to set email alerts
|

Potential-dependent electrochemiluminescence of luminol in alkaline solution at a gold electrode

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

5
63
0

Year Published

2004
2004
2016
2016

Publication Types

Select...
6

Relationship

4
2

Authors

Journals

citations
Cited by 58 publications
(68 citation statements)
references
References 15 publications
5
63
0
Order By: Relevance
“…2(b)) were observed at 0.31, 0.65 and 1.55 V, respectively. The ECL-1, ECL-2 and ECL-3 behaviors under linear sweep voltammetry under an air atmosphere were similar to the anodic ECL-1, ECL-2 and ECL-4 behaviors at a gold electrode under cyclic voltammetry under an oxygen atmosphere [10]. However, the corresponding potentials of the ECL-1, ECL-2 and ECL-3 under linear sweep voltammetry under an air atmosphere were more positive than those of the anodic ECL-1, ECL-2 and ECL-4 behaviors at a gold electrode under cyclic voltammetry under an oxygen atmosphere.…”
Section: Ecl-1 Behavior Under Cyclic Voltammetrysupporting
confidence: 54%
See 3 more Smart Citations
“…2(b)) were observed at 0.31, 0.65 and 1.55 V, respectively. The ECL-1, ECL-2 and ECL-3 behaviors under linear sweep voltammetry under an air atmosphere were similar to the anodic ECL-1, ECL-2 and ECL-4 behaviors at a gold electrode under cyclic voltammetry under an oxygen atmosphere [10]. However, the corresponding potentials of the ECL-1, ECL-2 and ECL-3 under linear sweep voltammetry under an air atmosphere were more positive than those of the anodic ECL-1, ECL-2 and ECL-4 behaviors at a gold electrode under cyclic voltammetry under an oxygen atmosphere.…”
Section: Ecl-1 Behavior Under Cyclic Voltammetrysupporting
confidence: 54%
“…The magnifying power of GD-1 luminometer was set to 10·, however, the magnifying power of GD-1 luminometer in our previous works [9,10] was set to 1·.…”
Section: Ecl and Electrochemical Measurementmentioning
confidence: 99%
See 2 more Smart Citations
“…Recently, multi-channel ECL under conventional cyclic voltammetric (CV) conditions has drawn great attention (1)(2)(3)(4)(5). In our previous research work (2)(3)(4)(5), the ECL of luminol has been studied at glass carbon (GC), platinum, gold and paraffin-impregnated graphite electrodes under CV conditions. Several ECL peaks were found on the curves of ECL intensity vs. applied potential (I ECL -E), dependent upon electrode potential, electrode material and electrode surface status.…”
Section: Introductionmentioning
confidence: 99%