2000
DOI: 10.1007/bf02756085
|View full text |Cite
|
Sign up to set email alerts
|

Potentialities of thermal lens spectrometry in studying peculiarities of reactions at the trace level

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2003
2003
2019
2019

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 47 publications
0
6
0
Order By: Relevance
“…A thorough, detailed study of all the factors affecting the accuracy of thermal lensing is still needed. However, a basic verification of the accuracy and bias of TLS, CB-TLS, and TLM was done in detail in previous reports [3,12,17,28]. It was shown that investigations of the thermal-lens signal as a function of the apparent molar absorptivity, excitation-beam wavelength, etc.…”
Section: Accuracy Of Thermal-lens Measurementsmentioning
confidence: 99%
See 1 more Smart Citation
“…A thorough, detailed study of all the factors affecting the accuracy of thermal lensing is still needed. However, a basic verification of the accuracy and bias of TLS, CB-TLS, and TLM was done in detail in previous reports [3,12,17,28]. It was shown that investigations of the thermal-lens signal as a function of the apparent molar absorptivity, excitation-beam wavelength, etc.…”
Section: Accuracy Of Thermal-lens Measurementsmentioning
confidence: 99%
“…It has already evolved into a highly sensitive and versatile analytical technique [1,2]. A primary feature of TLS is that its overall sensitivity (subnanogram LODs down to 10 -7 absorbance units) is achieved not only through instrumentation, but also because of better conditions for photometric reactions at trace levels [3]. Other key features of TLS, locality and high spatial resolution, have led to the vigorous use of thermal-lens microscopy (TLM) as a novel detection method [4][5][6][7].…”
Section: Introductionmentioning
confidence: 99%
“…1,2 Its high sensitivity is achieved not only through instrumentation, but also because of the reaction conditions at trace levels. 3 The locality and high spatial resolution of TLS have led to wide-scale applications of thermal-lens microscopy (TLM) as a state-of-the-art method. [4][5][6][7] TLM perfectly fits micro-totalanalytical systems (μTAS) (reactions and separations occurring at high rates in nanoscale volumes).…”
Section: Introductionmentioning
confidence: 99%
“…We have chosen Co and Fe determination because (i) the photometric methods for these metals are both sensitive and reliable; 24 (ii) they are based on the same reaction type, chelation; (iii) these methods cover all of the selected procedure types; and (iv) optimized TLS/TLM procedures have low practical LODs under batch and flow conditions. 3,4,[25][26][27][28][29][30][31][32][33][34][35][36] A total of 39 procedures (16 for Fe and 23 for Co) were considered.…”
Section: Introductionmentioning
confidence: 99%
“…This strategy proved very useful for another widespread photothermal method, thermal lensing. 14 In selecting the main target application, we considered the fact that trace determination of metals, particularly iron, in seawater is one of the topical tasks of marine chemistry. Iron is a very active participant in various biological and redox processes in seawater.…”
Section: Introductionmentioning
confidence: 99%