2005
DOI: 10.1016/j.aca.2004.10.046
|View full text |Cite
|
Sign up to set email alerts
|

Potentiometric flow injection analysis of dicyclomine hydrochloride in serum, urine and milk

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
14
0

Year Published

2006
2006
2016
2016

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 22 publications
(14 citation statements)
references
References 37 publications
0
14
0
Order By: Relevance
“…In previous studies we described a group of ion-exchangerbased PVC membrane electrodes, with liquid inner contact, for the selective determination of dicyclomine [1], mebeverine [2] and drotaverine [3]. The ion-exchanger incorporated in each electrode was an ion-association of the drug cation with the heteropoly anion silicotungstate, silicomolybdate, phosphotungstate or phosphmolybdate.…”
Section: Preliminary Studiesmentioning
confidence: 99%
See 3 more Smart Citations
“…In previous studies we described a group of ion-exchangerbased PVC membrane electrodes, with liquid inner contact, for the selective determination of dicyclomine [1], mebeverine [2] and drotaverine [3]. The ion-exchanger incorporated in each electrode was an ion-association of the drug cation with the heteropoly anion silicotungstate, silicomolybdate, phosphotungstate or phosphmolybdate.…”
Section: Preliminary Studiesmentioning
confidence: 99%
“…This is associated with the high molecular weights of these anions, which range from 1823 to 2880. In our previous works [1][2][3], the solubility product constants (K SP ) of these ionassociates were determined conductometrically [24] and the calculated solubility (S) values of these compounds revealed that the ion-associate dicyclomine-silicotungstate, mebeverinesilicotungstate and drotaverine-silicomolybdate have the lowest solubilities between the prepared ion-associates. Therefore, these compounds were selected in this study to be used as active recognition elements in the proposed CWEs.…”
Section: Preliminary Studiesmentioning
confidence: 99%
See 2 more Smart Citations
“…The mechanism of selectivity is mainly based on the electrostatic environment and it is dependent on how much fitting is present between the locations of the lipophilicity sites in the two competing species in the bathing solution side and those present in the receptor of the ion-exchanger. 22,23 Inorganic cations do not interfere because of differences in ionic size, mobility and permeability. The electrodes are also selective to PE + towards number of sugars, and amino acids.…”
Section: Selectivity Of the Electrodesmentioning
confidence: 99%