2008
DOI: 10.17660/actahortic.2008.779.35
|View full text |Cite
|
Sign up to set email alerts
|

Pourthru: A Method for Monitoring Nutrition in the Greenhouse

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
62
2
9

Year Published

2013
2013
2023
2023

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 57 publications
(73 citation statements)
references
References 0 publications
0
62
2
9
Order By: Relevance
“…Only when nutrients solutions containing at least 8 mmol L −1 of K, independently of the N concentration, or solutions with 16 mmol L −1 of N and a minimum of 6 mmol L −1 of K or 20 mmol L −1 of N and any K concentration, the substratum CE reached values close to the inferior limit of the range considered adequate by Baumgarten [18], that is, from 0.8 to 1.5 dS m −1 and by Cavins et al [20], that is, from 0.76 to 1.5 dS m −1 as determined by the extraction methods by dilution 1 : 1,5 v/v and 1.2 v/v, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…Only when nutrients solutions containing at least 8 mmol L −1 of K, independently of the N concentration, or solutions with 16 mmol L −1 of N and a minimum of 6 mmol L −1 of K or 20 mmol L −1 of N and any K concentration, the substratum CE reached values close to the inferior limit of the range considered adequate by Baumgarten [18], that is, from 0.8 to 1.5 dS m −1 and by Cavins et al [20], that is, from 0.76 to 1.5 dS m −1 as determined by the extraction methods by dilution 1 : 1,5 v/v and 1.2 v/v, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…Uma das técnicas adotadas no manejo da fertirrigação é o monitoramento do lixiviado ou Pour-Through (CAVINS et al, 2008), cujos diferentes atributos podem ser avaliados, como a condutividade elétrica (CE) e as concentrações de diferentes íons. A CE resulta da presença dos íons em solução e é diretamente relacionada com a concentração destes (HELBEL JUNIOR et al, 2008 Manejo da solução nutritiva sobre a qualidade pós-colheita de tomate salada fertirrigado em areia Takahashi, H. W. et al N, P, K, Ca, Mg e S do lixiviado foram obtidas de acordo com as metodologias descritas por Silva (2009).…”
Section: Introductionunclassified
“…Leachate was collected in each irrigation event from pots using the PT method (Cavins et al, 2008). Thirty minutes after the crop had been irrigated 90 mL of distilled water was poured evenly over the surface of the substrate by hand and the extract was allowed to drain for 10 minutes, obtaining around 40 mL of leachate.…”
Section: Measurements Of Ec Using the Pour-through Methodsmentioning
confidence: 99%
“…While growers habitually record average EC L values from various pots in an irrigation zone (the leachate is easy to collect), EC L records rarely coincide with those of EC PW , because EC L depends on factors such as the leaching fraction, irrigation water salinity, the physical characteristics of the substrate and environmental conditions Hershey, 1991, Torres et al, 2010). Another way of measuring EC PW on-site is the pour-through (PT) method, which was described by Wright (1986) and adapted by Cavins et al (2008). Pourthrough extraction occurs by displacement of the root zone solution by distilled water poured over the top of a substrate as a means to obtain a soil solution sample.…”
Section: Introductionmentioning
confidence: 99%