2006 IEEE Vehicle Power and Propulsion Conference 2006
DOI: 10.1109/vppc.2006.364357
|View full text |Cite
|
Sign up to set email alerts
|

Power Management of an Ultracapacitor/Battery Hybrid Energy Storage System in an HEV

Abstract: To overcome the power delivery limitations of The optimal design of a HESS has been the topic of many batteries and energy storage limitations of ultracapacitors, papers. Researchers [10][11] have considered a direct parallel hybrid energy storage systems, which combine the two energy connection of the two sources. This setup keeps the same sources, have been proposed. A comprehensive review of the voltage over both sources, which in tur limits the power state of the art is presented. In addition, a method of … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
88
0
5

Year Published

2011
2011
2020
2020

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 211 publications
(93 citation statements)
references
References 17 publications
0
88
0
5
Order By: Relevance
“…This type of system allows different ESECS to function at their most efficient operating point and therefore increases the overall system efficiency [6,7,8,9,10,11,12,13,14]. The Toyota Prius drivetrain is an example of such a system.…”
Section: Linkage Of Multiple Energy Storage Systems and Energy Convermentioning
confidence: 99%
“…This type of system allows different ESECS to function at their most efficient operating point and therefore increases the overall system efficiency [6,7,8,9,10,11,12,13,14]. The Toyota Prius drivetrain is an example of such a system.…”
Section: Linkage Of Multiple Energy Storage Systems and Energy Convermentioning
confidence: 99%
“…Recently, to solve the problem of the shorter life cycles of the lead-acid batteries for EVs (electric vehicles), which is caused by continuous charging and discharging, several studies have been performed using discharge control circuits to improve their efficiency and longevity [13]- [23]. Fig.…”
Section: A Study On Discharge Efficiency Using Hessmentioning
confidence: 99%
“…Since the forecasting of wind speed and the time when wind blows is too difficult due to the fact that wind speed is an uncertain parameter, wind power generation would be Storage System (ESS) [93][94][95][96][97][98][99][100][101]. The most common ESS is battery.…”
Section: -Wind With Phevsmentioning
confidence: 99%
“…In this scheme, two BESSs are considered where the generated power by wind turbines is used to charge one BESS while the other one is used to discharge power into the electric grid at a fixed rate. For far residential areas with small demands, stand-alone wind power generation along with a battery bank as energy storage are used that are necessary for sustainable and reliable supply [94,132]. For this system, load is a battery which can be considered as energy sink with almost fixed voltage while it is able to absorb power at any level until the charging current is in range.…”
Section: -Wind-batterymentioning
confidence: 99%