2016
DOI: 10.1109/tpwrd.2015.2427878
|View full text |Cite
|
Sign up to set email alerts
|

Power Oscillation Damping From VSC–HVDC Connected Offshore Wind Power Plants

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
58
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
3
2
2

Relationship

1
6

Authors

Journals

citations
Cited by 65 publications
(58 citation statements)
references
References 11 publications
0
58
0
Order By: Relevance
“…It is a service that improves damping of electromechanical oscillations (typically 0.2 − 2 Hz) in an ac grid by injecting a damping power. VSC-HVDC converter can achieve POD by modulating either active or reactive powers [1], [2]. It was found in [2] that active power modulation gives more robust performance regarding ac voltage variations.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…It is a service that improves damping of electromechanical oscillations (typically 0.2 − 2 Hz) in an ac grid by injecting a damping power. VSC-HVDC converter can achieve POD by modulating either active or reactive powers [1], [2]. It was found in [2] that active power modulation gives more robust performance regarding ac voltage variations.…”
Section: Introductionmentioning
confidence: 99%
“…VSC-HVDC converter can achieve POD by modulating either active or reactive powers [1], [2]. It was found in [2] that active power modulation gives more robust performance regarding ac voltage variations. However, a side effect of using active power is that the oscillation is exported to the dc side since active power is balanced instantaneously.…”
Section: Introductionmentioning
confidence: 99%
“…[9,29,30] mention a different control strategy based on direct control of the AC voltage. The lack of a dedicated fast current controller is compensated by limiting the voltage drop over the converter impedance to e.g.…”
Section: Offshore Vsc-hvdc Controlmentioning
confidence: 99%
“…and offshore grid operations [31]. This allows to use the beneficial feed-forward of the load current in the voltage control [30]. The effective capacitance of the offshore grid in combination with gain scheduling might allow its avoidance [29] but is outside the scope of this study.…”
Section: Offshore Vsc-hvdc Controlmentioning
confidence: 99%
“…However, to avail such type of voltage support service from WPPs, high speed measurement and communication infrastructure will be required [12]. Moreover, in the literature [6]- [12], different ancillary services from OWPPs (i.e.…”
Section: Introductionmentioning
confidence: 99%