2021 1st International Conference on Power Electronics and Energy (ICPEE) 2021
DOI: 10.1109/icpee50452.2021.9358692
|View full text |Cite
|
Sign up to set email alerts
|

Power quality improvement with D-STATCOM using combined PR and Comb filter- Controller

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(2 citation statements)
references
References 8 publications
0
2
0
Order By: Relevance
“…6 Figure 2 shows types of SST.When non-linear loads and power electronics equipment are used excessively at the (PCC), harmonic currents are generated, which reduce the quality of the electrical power. 7 The DC-link capacitor, located on the front of the VSI, is used to manage reactive power for the grid. 8 The most commonly used controller in business is the proportional-integral-derivative (PID) controller, but it only performs properly when its settings are correctly tuned.While conventional approaches like Ziegler-Nichols and pole placement have been employed historically for achieving this objective, there has been a growing trend in the adoption of state-of-the-art techniques such as heuristic optimization algorithms in recent times.…”
Section: Introductionmentioning
confidence: 99%
“…6 Figure 2 shows types of SST.When non-linear loads and power electronics equipment are used excessively at the (PCC), harmonic currents are generated, which reduce the quality of the electrical power. 7 The DC-link capacitor, located on the front of the VSI, is used to manage reactive power for the grid. 8 The most commonly used controller in business is the proportional-integral-derivative (PID) controller, but it only performs properly when its settings are correctly tuned.While conventional approaches like Ziegler-Nichols and pole placement have been employed historically for achieving this objective, there has been a growing trend in the adoption of state-of-the-art techniques such as heuristic optimization algorithms in recent times.…”
Section: Introductionmentioning
confidence: 99%
“…In [30], the authors have investigated the execution of D-STATCOM for reactive power compensation required by doubly-fed wind farm linked to the grid. The power quality concerns alleviated by D-STATCOM in [31] employing PR control and comb filter during unbalanced and non-linear scenarios. Though, the linear control strategies have major limitations such as tuning of control constraints, inadequate transient response [32], and deficient reference tracking in the situation of challenging a significant error [33].…”
mentioning
confidence: 99%