2019
DOI: 10.1049/iet-cps.2018.5014
|View full text |Cite
|
Sign up to set email alerts
|

Power system effects and mitigation recommendations for DER cyberattacks

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
20
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 44 publications
(20 citation statements)
references
References 22 publications
0
20
0
Order By: Relevance
“…In [18], an attempt is conducted to investigate the impact on the cyber-physical power grid in cases where communications and operations of distributed energy resources are manipulated by an adversary. In [19], research is conducted to assess the dynamic impacts of hypothesised cyber attacks on substations and concluded that the dynamic study is more capable in detecting cascading failure due to cyber attacks.…”
Section: Introductionmentioning
confidence: 99%
“…In [18], an attempt is conducted to investigate the impact on the cyber-physical power grid in cases where communications and operations of distributed energy resources are manipulated by an adversary. In [19], research is conducted to assess the dynamic impacts of hypothesised cyber attacks on substations and concluded that the dynamic study is more capable in detecting cascading failure due to cyber attacks.…”
Section: Introductionmentioning
confidence: 99%
“…We use the engineering controls adapted from [54] to prevent potentially harmful Volt-VAR curves from being set by an adversary. The determination of the boundaries for allowed and disallowed points is made by the placement of V ref and the zero reactive power line, where V ref is the reference voltage.…”
Section: Volt-var Detectionmentioning
confidence: 99%
“…The modified settings represented situations where the PV inverters were improperly programmed to injected reactive power at high voltage. This altered setting could be disallowed in future software implementations as described by Johnson et al [14], but as of today the capability exists.…”
Section: Volt-var Curve Control Parameter Settingsmentioning
confidence: 99%
“…Quiroz et al used the same OpenDSS feeder model to test VVC control strategies that countered the impact of two large PV systems [30]. The model was also used in a cyber-attack consequence tests [14], which described the impact of a potential attack on the VVC at a given integration scenario.…”
Section: Feeder Modelmentioning
confidence: 99%