2021
DOI: 10.1002/9781119513100
|View full text |Cite
|
Sign up to set email alerts
|

Power System Protection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
25
0
3

Year Published

2022
2022
2024
2024

Publication Types

Select...
4
2
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 62 publications
(28 citation statements)
references
References 0 publications
0
25
0
3
Order By: Relevance
“…Sensitivity is the ability of the protection system to quickly detect and isolate faults before the power grid's stability margins are violated. Selectivity is the capability of the protection system to isolate the fault such that the least number of loads are affected by a power outage [1]. As discussed in [2]- [4], the role of protection system is to enhance the power system's reliability and resilience and to avoid major outages with possible cascading effects.…”
Section: Introductionmentioning
confidence: 99%
“…Sensitivity is the ability of the protection system to quickly detect and isolate faults before the power grid's stability margins are violated. Selectivity is the capability of the protection system to isolate the fault such that the least number of loads are affected by a power outage [1]. As discussed in [2]- [4], the role of protection system is to enhance the power system's reliability and resilience and to avoid major outages with possible cascading effects.…”
Section: Introductionmentioning
confidence: 99%
“…The majority of the feeder's loads are situated on the laterals. The feeder is the inherently unbalanced because of the unequal (unequality) spacing of the laterals and uneven distribution of the single phase loads [2]. The current built up very quickly because of shunt faults in power system.…”
Section: Introductionmentioning
confidence: 99%
“…The secondary or backup relay should take over tripping only if the main relay fails to operate fails to operate. The relay may get mal operated if backup relays are not properly coordinated [1,2].The purpose of relay coordination is to ensure that in the event of a power system failure, the protective relay is required to isolate only the faulty part of the power system from the healthy network and should operate as quickly as possible to keep the healthy network of the system in normal condition. Optimal relay coordination can be achieved by selecting optimal relay settings, namely Plug Setting (PS)and Time Multiplier Setting (TMS).…”
Section: Introductionmentioning
confidence: 99%
“…Long transmission lines are generally protected by distance protection as both main and backup protection. A distance relay can be categorized based on its operating zone characteristics, like quadrilateral, elliptical, lenticular, polygonal, and mho-based protection scheme [1]. The characteristic of a distance relay is defined during the commissioning of a protection system considering different network contingencies.…”
Section: Introductionmentioning