2018
DOI: 10.1016/j.epsr.2018.07.008
|View full text |Cite
|
Sign up to set email alerts
|

Power system protection with digital overcurrent relays: A review of non-standard characteristics

Abstract: DOI to the publisher's website.• The final author version and the galley proof are versions of the publication after peer review.• The final published version features the final layout of the paper including the volume, issue and page numbers. Link to publication General rightsCopyright and moral rights for the publications made accessible in the public portal are retained by the authors and/or other copyright owners and it is a condition of accessing publications that users recognise and abide by the legal re… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
41
0
4

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 82 publications
(45 citation statements)
references
References 94 publications
0
41
0
4
Order By: Relevance
“…Power system protection schemes are the final defense for preventing the cascading events [19,20]. Under frequency load shedding (UFLS) and under voltage load shedding (UVLS) techniques are in use to maintain the frequency and voltage of the system in case of large disturbances.…”
Section: An Overview and Motivationsmentioning
confidence: 99%
See 1 more Smart Citation
“…Power system protection schemes are the final defense for preventing the cascading events [19,20]. Under frequency load shedding (UFLS) and under voltage load shedding (UVLS) techniques are in use to maintain the frequency and voltage of the system in case of large disturbances.…”
Section: An Overview and Motivationsmentioning
confidence: 99%
“…From the onset of frequency/voltage decline, up until the predefined threshold is violated, there is a small time window to implement all required restorative actions [21][22][23]. Protective schemes have been implemented for different power systems across the world [19]. They are aimed at preventing the system from further separation in the event of a disturbance [20,24].…”
Section: An Overview and Motivationsmentioning
confidence: 99%
“…The OC relays are used as the main protection devices for radial distribution systems [30]. An OC relay measures the current flowing through it and determines whether to send a signal to open a circuit breaker [26,36].…”
Section: Settings Of Protective Devicesmentioning
confidence: 99%
“…In [20], the concept of non-standard features for overcurrent protection coordination in power systems is described. Non-standard features are those not described neither in IEEE nor in IEC (international electrotechnical commission) standards.…”
Section: Introductionmentioning
confidence: 99%