1981
DOI: 10.1109/mper.1981.5511219
|View full text |Cite
|
Sign up to set email alerts
|

Power System State Estimation: Detection of Topological Errors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0
1

Year Published

2017
2017
2021
2021

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(8 citation statements)
references
References 0 publications
0
7
0
1
Order By: Relevance
“…One is the topological method and the other is the numerical method. 8,10 Conversant with network reduction concepts and its methods Upstream modeling of the desired network for the implementation of SE is a main challenge of a PAS engineer. In this aim, the student must be able to model upstream network to have the best estimation and best results.…”
Section: Conversant With Observability Concepts and Its Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…One is the topological method and the other is the numerical method. 8,10 Conversant with network reduction concepts and its methods Upstream modeling of the desired network for the implementation of SE is a main challenge of a PAS engineer. In this aim, the student must be able to model upstream network to have the best estimation and best results.…”
Section: Conversant With Observability Concepts and Its Methodsmentioning
confidence: 99%
“…This technique is known as the weighted least squares (WLS) method. [7][8][9][10][11] Supervisory control and data acquisition SCADA aids PAS engineers in controlling the vast amounts of information entering and leaving power plants and electrical substations in order to help facilitate the delivery of electricity. The system tracks values of devices, such as transformers, overhead lines, shunt devices, breakers, and generators, and processes these values as points.…”
Section: State Estimationmentioning
confidence: 99%
“…State estimation and topology detection have co-evolved since at least the late 1970s [3]; see [4] for an overview of the state of the art as of 2000. These industry-standard methods use low time-resolution SCADA data about power flows and digital status, together with a reference model, to infer system voltages and currents as well as the current topology.…”
Section: B Prior Workmentioning
confidence: 99%
“…Liao In transmission grids, the grid topology is usually available to system operators. The topology error caused by the infrequent reconfiguration can be identified by the topology processor and state estimation [3]- [5]. Unfortunately, in medium voltage (MV) and low voltage (LV) distribution grids, a topology can frequently change and make existing methods with limited performance.…”
Section: Introductionmentioning
confidence: 99%