1981
DOI: 10.1007/bf01419247
|View full text |Cite
|
Sign up to set email alerts
|

Pr�ziseQ ? -Wert-Messungen mit einem Intrinsic-Germanium-Detektor an schweren, neutronenreichen Spaltprodukten

Abstract: An intrinsic germanium detector was used to measure the beta endpoint energies of heavy fission products supplied by the on line mass separator OSTIS installed at the high flux reactor of the Institut Max von Laue-Paul Langevin, Grenoble. The endpoints of singles-spectra have been determined and, by means of beta-gamma coincidence measurements also most of the Ot~-values of the following neutron-rich nuclides could be deduced with high accuracy:

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
12
3
1

Year Published

1982
1982
1992
1992

Publication Types

Select...
5
1

Relationship

2
4

Authors

Journals

citations
Cited by 33 publications
(18 citation statements)
references
References 19 publications
2
12
3
1
Order By: Relevance
“…In the fifth column of this table, an "adopted value" has been calculated for those nuclei, for which at least two different Q~-measurements have been reported. In the calculation of these adopted values, the experimental errors in the study of Decker et al [10] have been multiplied by a factor of two in all cases, where these errors are below 50keV. This was done, because important systematic errors, especially those due to the detector response function, have not been taken into account correctly in the calculation of the experimental errors in [10].…”
Section: ~*'71n 57~d90mentioning
confidence: 99%
See 2 more Smart Citations
“…In the fifth column of this table, an "adopted value" has been calculated for those nuclei, for which at least two different Q~-measurements have been reported. In the calculation of these adopted values, the experimental errors in the study of Decker et al [10] have been multiplied by a factor of two in all cases, where these errors are below 50keV. This was done, because important systematic errors, especially those due to the detector response function, have not been taken into account correctly in the calculation of the experimental errors in [10].…”
Section: ~*'71n 57~d90mentioning
confidence: 99%
“…In the calculation of these adopted values, the experimental errors in the study of Decker et al [10] have been multiplied by a factor of two in all cases, where these errors are below 50keV. This was done, because important systematic errors, especially those due to the detector response function, have not been taken into account correctly in the calculation of the experimental errors in [10]. In the last column of Table 2, the Qp-values from "The 1983 Mass Table" are presented.…”
Section: ~*'71n 57~d90mentioning
confidence: 99%
See 1 more Smart Citation
“…e a r l i e r [ 5 ] and a n a l y s i s o f t h e d e t e c t o r d i s t o r t e d d a t a has been accomplished t h r o u g h an i t e r a t i v e technique 161. It has a l s o been demonstrated t h a t a .…”
Section: T R I N S I C Germanium D E T E C T O R Has Been Developed Amentioning
confidence: 99%
“…I n t h e i r e a r l i e r work, Decker e t a l . ' [4,5] e x p e r i m e n t a l l y s t u d i e d t h e e l e c t r o n response o f Ge u s i n g m o n e r g e t i c ' e l e c t r o n s . .…”
Section: Mated T H E E F F E C T S O F T H E -B a C K S C A T T E R Aunclassified