2011
DOI: 10.1515/cclm.2011.249
|View full text |Cite
|
Sign up to set email alerts
|

Practical application of Sigma Metrics QC procedures in clinical chemistry

Abstract: The use of the road map based on Sigma Metrics leads to fast and easy implementation of optimal Westgard QC rules.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
43
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 53 publications
(43 citation statements)
references
References 5 publications
0
43
0
Order By: Relevance
“…[5] Schoenmaker et al described the importance of application of sigma metrics and preparation of rational QC design based on the sigma values with the help of westgard operational specifications chart (OPSpecs chart) in clinical biochemistry laboratories. [9] An example of QC design is shown in the Table 8. IJBR (2015) 6 (03) www.ssjournals.com IJBR (2015) 6 (03) www.ssjournals.com …”
Section: Discussionmentioning
confidence: 99%
“…[5] Schoenmaker et al described the importance of application of sigma metrics and preparation of rational QC design based on the sigma values with the help of westgard operational specifications chart (OPSpecs chart) in clinical biochemistry laboratories. [9] An example of QC design is shown in the Table 8. IJBR (2015) 6 (03) www.ssjournals.com IJBR (2015) 6 (03) www.ssjournals.com …”
Section: Discussionmentioning
confidence: 99%
“…We used both precision and bias to generate several outcome metrics, including patient-weighted metrics, in-control percentage unreliable patient results, and maximum expected number of unreliable patient results due to an out-of-control condition [Max E(N uf )]. Sigma values are directly related to the predicted probability of producing unreliable patient results during stable operation, which may be expressed in terms of defects per million opportunities (DPMO) (7 ). A 6-method is associated with 3.4 DPMO and is classified as "world class quality."…”
Section: Discussionmentioning
confidence: 99%
“…This Equivalent QC option will be discontinued in 2016. Recently, the Centers for Medicare and Medicaid Services announced a new type of QC plan, the Individualized QC Plan (IQCP), 7 beginning January 2014, that allows laboratories to utilize risk management strategies to design a QC program. Laboratories will be able to choose either the traditional approach of testing 2 levels of QC per assay, per day of patient testing, or they may elect to develop the newly introduced IQCP, which determines analytical QC frequency by utilizing risk management principles.…”
mentioning
confidence: 99%
“…Since the introduction of the Six Sigma concept into clinical laboratories (12 ), several recommendations have been made for selecting optimal SQC procedures considering only the of the analytical process (13)(14)(15). Unless there is some exception (13 ), none of these recommendations take into account the QC frequency or the laboratory testing mode, but most of the SQC procedures recommended for control analytical processes with a certain show low Max E(N UF ) values (typically below 1 in the nomogram of Fig.…”
Section: Discussionmentioning