2016
DOI: 10.1039/c6ay01231k
|View full text |Cite
|
Sign up to set email alerts
|

Pre-concentration of Ta(V) by solvent extraction before determination of trace amounts of Ta in Nb and Nb compounds

Abstract: The paper presents the results of a study on the efficiency of the separation of Ta(V) and Nb(v) from fluoride solutions by solvent extraction with methyl isobutyl ketone with a view to applying the extraction process to the purification of Nb from Ta and for the pre-concentration of Ta prior to its determination in Nb and its compounds over a wide range of initial concentrations.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 16 publications
0
5
0
Order By: Relevance
“…Based on our previous studies of tantalum determination in the niobium matrix [41,42], depending on the tantalum content in niobium, Ta determination was performed using a Varian 810-MS inductively coupled plasma mass spectrometer (ICP-MS) (Varian, Palo Alto, CA, USA) (<3 ppm Ta in Nb) or a iCAP 7400+ MFC Duo inductively coupled plasma atomic emission spectrometer (ICP-AES) (Thermo) (>3 ppm Ta in Nb) equipped with a Duo EMT Torch Kit, cyclonic spray chamber, and sea spray nebulizer. The standards of tantalum with proper niobium matrix concentration were used.…”
Section: Apparatusmentioning
confidence: 99%
See 4 more Smart Citations
“…Based on our previous studies of tantalum determination in the niobium matrix [41,42], depending on the tantalum content in niobium, Ta determination was performed using a Varian 810-MS inductively coupled plasma mass spectrometer (ICP-MS) (Varian, Palo Alto, CA, USA) (<3 ppm Ta in Nb) or a iCAP 7400+ MFC Duo inductively coupled plasma atomic emission spectrometer (ICP-AES) (Thermo) (>3 ppm Ta in Nb) equipped with a Duo EMT Torch Kit, cyclonic spray chamber, and sea spray nebulizer. The standards of tantalum with proper niobium matrix concentration were used.…”
Section: Apparatusmentioning
confidence: 99%
“…The standards of tantalum with proper niobium matrix concentration were used. The niobium compound used as the matrix was purified from Ta by solvent extraction [42]. The parameters for tantalum analysis using the ICP-AES apparatus were as follows: RF power 1.35 kW, plasma flow 12 L/min, coolant gas flow 14 L/min, auxiliary gas flow 0.5 L/min, nebulizer gas flow 0.4 L/min, pump rate 80 rpm, and emission lines λ Ta = 233.1, 240.0, and 263.5 nm.…”
Section: Apparatusmentioning
confidence: 99%
See 3 more Smart Citations