Abstract: Prediction ability of near infrared (NIR) spectroscopy for intramuscular fat content (IMF) determination was studied. The material comprised 126 muscle samples; 46 pig longissimus dorsi and semitendinosus and 34 beef longissimus dorsi muscle samples. The IMF content was chemically determined in duplicate using two different chemical methods; fat extraction according to Folch et al. and Soxhlet extraction with hydrolysis according to SIST ISO 1443. Folch extraction underestimated IMF content compared to Soxhlet… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
30
1
1

Year Published

2009
2009
2020
2020

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 58 publications
(34 citation statements)
references
References 21 publications
2
30
1
1
Order By: Relevance
“…In our case, RPD and RER were higher than those limits. Results on the accuracy of calibration equation for predicting fat content are similar to previous works in rabbit (Masoero et al, 1994;Pla et al, 2004), poultry (Abeni and Bergoglio, 2001), beef and pork meat (Prevolnik et al, 2005). Table 2 shows descriptive statistics of IMF content measured by chemical analysis and predicted by NIRS.…”
Section: Nirs Calibration For Intramuscular Fatsupporting
confidence: 83%
“…In our case, RPD and RER were higher than those limits. Results on the accuracy of calibration equation for predicting fat content are similar to previous works in rabbit (Masoero et al, 1994;Pla et al, 2004), poultry (Abeni and Bergoglio, 2001), beef and pork meat (Prevolnik et al, 2005). Table 2 shows descriptive statistics of IMF content measured by chemical analysis and predicted by NIRS.…”
Section: Nirs Calibration For Intramuscular Fatsupporting
confidence: 83%
“…Drip loss was determined after 24-and 48-hour storage at 4°C and expressed as a percentage of the initial weight. The intramuscular fat content of LD was estimated in minced samples using NIRS (NIR System Model 6500 Spectrometer, Silver Spring, MD, USA) as described in Prevolnik et al (2005).…”
Section: Carcass and Meat Quality Measurementsmentioning
confidence: 99%
“…The best results were from Prevolnik et al [137] where the coefficient of determination value was over 0.9. Very poor results were obtained by Tornberg et al [134] when no preprocessing was used with VIS (400-800 nm) whereas NIR (800-2500 nm) provided almost twice as good results.…”
Section: B15 Dietmentioning
confidence: 97%
“…The intramuscular fat is important quality factor which has been studied for beef [130,136,137] and pork [133,137]. Sierra et al [136] studied the composition and content of intramuscular fat has been studied by using NIR transmittance 850 to 1050 nm.…”
Section: B15 Dietmentioning
confidence: 99%
See 1 more Smart Citation