2015
DOI: 10.1255/ejms.1389
|View full text |Cite
|
Sign up to set email alerts
|

Prediction of Adducts on Positive Mode Electrospray Ionization Mass Spectrometry: Proton/Sodium Selectivity in Methanol Solutions

Abstract: We used positive mode electrospray ionization (ESI) mass spectrometry to examine 540 in-house high-resolution mass spectrometry (HRMS) samples that formed an adducted positive ion. Of the 540 samples, the sodium adduct ([M+Na]⁺) was detected in 480 samples, and the protonated molecule ([M+H]⁺) was detected in 92 samples; both [M+Na]⁺ and [M+H]⁺ were detected in 32 samples. No other adduct ions were predominant. The selectivities of these adducts were evaluated by a two-dimensional plot using topological polar … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 14 publications
(17 citation statements)
references
References 22 publications
0
17
0
Order By: Relevance
“…Besides, on comparison with our previous study with regard to adduct selectivity on ESI using the same sample set, [M þ H] þ group of ESI almost overlapped [M þ H] þ group of DART. 17 In contrast, spreading of [M þ H] þ group of DART on a twodimensional scatter plot using the MW and tPSA values were extremely wide. It suggests that DART adduct selectivity is not simply dependent on the elemental composition.…”
Section: Polarity Evaluationmentioning
confidence: 97%
See 4 more Smart Citations
“…Besides, on comparison with our previous study with regard to adduct selectivity on ESI using the same sample set, [M þ H] þ group of ESI almost overlapped [M þ H] þ group of DART. 17 In contrast, spreading of [M þ H] þ group of DART on a twodimensional scatter plot using the MW and tPSA values were extremely wide. It suggests that DART adduct selectivity is not simply dependent on the elemental composition.…”
Section: Polarity Evaluationmentioning
confidence: 97%
“…A chemical library was constructed by collecting samples submitted to our contracted HRMS measurement service. 15,17,18 The library samples were gathered from June 2012 to March 2013, and 611 samples were obtained. The identities of all the compounds in the sample library were confirmed by HRMS using ESI time-of-flight mass spectrometry (a few samples were confirmed using a FAB sector mass spectrometer) with errors of <5 ppm compared with the elemental compositions declared by the clients of the HRMS measurement service.…”
Section: In-house Chemical Librarymentioning
confidence: 99%
See 3 more Smart Citations