Prediction of Air Conditioning Load Response for Providing Spinning Reserve - ORNL Report

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2010
2010
2019
2019

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(11 citation statements)
references
References 3 publications
0
11
0
Order By: Relevance
“…There are a number of statistical approaches that can be used to correlate historical temperature data with total load (FERC 2009;Valor 2001). Utilities commonly use commercial software packages that project total load based on weather forecasts and historical demand patterns combined with heuristics and experience to produce accurate day-ahead forecasts of total load (Kueck et al 2008).…”
Section: Traditional Methods For Estimating Hourly Cooling Demandsmentioning
confidence: 99%
See 1 more Smart Citation
“…There are a number of statistical approaches that can be used to correlate historical temperature data with total load (FERC 2009;Valor 2001). Utilities commonly use commercial software packages that project total load based on weather forecasts and historical demand patterns combined with heuristics and experience to produce accurate day-ahead forecasts of total load (Kueck et al 2008).…”
Section: Traditional Methods For Estimating Hourly Cooling Demandsmentioning
confidence: 99%
“…DR can rapidly reduce electricity demand and provide operating reserves such as frequency regulation, contingency spinning reserves, and load-following reserves (Kueck et al 2008).…”
Section: Introductionmentioning
confidence: 99%
“…Residential air conditioners have been evaluated for providing spinning reserve services [14], and a pilot study successfully bid commercial building demand response into day-ahead non-spinning reserve markets [15].…”
Section: Commercial Buildingsmentioning
confidence: 99%
“…In order to provide a fast power demand response to the grid from the commercial building especially from the HVAC systems, the possibility and the availability of treating building power demands (e.g., power demands of air conditioning) as spinning/non-spinning "reserves" is also presented (Kueck et al 2009;Kiliccote et al 2011). For instance, Hao et al (2013) considered that 15% of fan power capacity in the HVAC system can be deployed for regulation purposes while having little effect on the building indoor air temperature.…”
Section: Number Duration Ofmentioning
confidence: 99%