Predictive accuracy of single‐ and multi‐slice MRI for the estimation of total visceral adipose tissue in overweight to severely obese patients

Abstract: The quantification of visceral adipose tissue (VAT) is increasingly being considered for risk assessment and treatment monitoring in obese patients, but is generally time-consuming. The goals of this work were to semi-automatically segment and quantify VAT areas of MRI slices at previously proposed anatomical landmarks and to evaluate their predictive power for whole-abdominal VAT volumes on a relatively large number of patients. One-hundred and ninety-seven overweight to severely obese patients (65 males; bod… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

7
44
1
3

Year Published

2015
2015
2020
2020

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 47 publications
(55 citation statements)
references
References 37 publications
7
44
1
3
Order By: Relevance
“…Furthermore, in this study, we used Bland-Altman analysis to assess the accuracy of our VAT volume prediction equation. Only one study by Schaudinn et al 22 ) investigated a prediction equation for VAT volume in obese patients. They showed a mean VAT bias between −55~232 ml for males and −61~161 ml for females.…”
Section: Discussionmentioning
confidence: 99%
“…Furthermore, in this study, we used Bland-Altman analysis to assess the accuracy of our VAT volume prediction equation. Only one study by Schaudinn et al 22 ) investigated a prediction equation for VAT volume in obese patients. They showed a mean VAT bias between −55~232 ml for males and −61~161 ml for females.…”
Section: Discussionmentioning
confidence: 99%
“…Data acquisition protocols for AT quantification vary from the use of a single-slice [124], a stack of slices (2D multi-slice or 3D volume acquisition) across a limited anatomical region (typically the abdomen) [125], or a whole body (head-to-feet) approach [37, 126]. Protocols centered at and about the L2-L3 and L4-L5 lumbar intervertebral spaces, as well as at the umbilicus, are the most popular choices for single and multi-slice protocols in CT and MRI.…”
Section: Single-slice Regional Multi-slice and Whole Body Acquisitionsmentioning
confidence: 99%
“…Measurements of total AT area at the level of the head of the humerus and at the head of the femur yielded similarly strong correlations with total body AT volumes. Schaudinn et al [125] recently evaluated the predictive accuracy of single and multi-slice MRI in the estimation of abdominopelvic VAT volume in 197 overweight and obese patients (BMI range 25–39 kg/m 2 ) using a 10-mm slice thickness and a small 0.5-mm interslice gap, nearly-contiguous protocol. Single-slice area measurements were made at the level of each of the following landmarks: intervertebral spaces at L1 through L5 and at S1, umbilicus, and femoral head.…”
Section: Single-slice Regional Multi-slice and Whole Body Acquisitionsmentioning
confidence: 99%
“…Prethodne studije su zasnovane na činjenici da se mrko masno tkivo razlikuje od belog po frakciji zasićenih i nezasićenih masnih kiselina, kao i sadržaju vode [48]. Smatra se da se volumen ukupnog supkutanog masnog tkiva može se proceniti jednim poprečnim presekom na nivou L5-S1 ili 5 cm ispod [47,49]. Razlikujemo nekoliko vrsta magnetne resonance, koje se koriste u zavisnosti od ciljeva istraživanja i dostupnosti same metode.…”
Section: Pletizmografija Istiskivanjem Vazduha (Bod Pod)unclassified
“…Danas se magnetna rezonanca jačine 1,5 do 3 Tesla koristi u večini kliničkih istraživanja, dok se skeneri jačine 7 Tesla sve više koriste u specijalizovanim centrima, gde se sprovode imidžing i spektorskopske eksperimentalne studije. Selektivna magnetna rezonanca u kombinaciji sa magnetnom rezonancom celog tela može da razdvaja i kvantifikuje volumene grupa adipocita pronađenih u skeletnom mišićnom kompartmanu, kao i količinu triglicerida u i izvan skeletnih mišićnih vlakana [49]. Kvanititativna magnetna rezonanca je dragocen metod za kvantifikovanje malih promena u masnoj masi [50].…”
Section: Pletizmografija Istiskivanjem Vazduha (Bod Pod)unclassified