Preliminary Design and Experimental Studies of a Novel Soft Implant for Correcting Sagittal Plane Instability in the Lumbar Spine

Abstract: A circular silicone spacer placed between the spinous processes appears to contribute to the stability of the cadaveric lumbar spine. There are many attractions to using a simple, soft implant that can be placed with minimal surgery between the spinous processes.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
47
0
3

Year Published

2008
2008
2013
2013

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 92 publications
(53 citation statements)
references
References 32 publications
2
47
0
3
Order By: Relevance
“…With the exception of a few studies, all of the biomechanical and clinical studies address cranial segment degeneration [15,39], because ASD caudal to a fusion is significantly less common [10]. The explanation for this is that in the adjacent segment cephalad to a fusion there is increased mobility compared with the adjacent caudal segment [5].…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…With the exception of a few studies, all of the biomechanical and clinical studies address cranial segment degeneration [15,39], because ASD caudal to a fusion is significantly less common [10]. The explanation for this is that in the adjacent segment cephalad to a fusion there is increased mobility compared with the adjacent caudal segment [5].…”
Section: Discussionmentioning
confidence: 99%
“…In this study, the vertebral segment cephalad to instrumented fusion was selected for several documented reasons: (1) this is the most frequent localisation of ASD [3]; (2) lumbosacral instrumented fusion is very rare (\3%) [15]; and (3) with exception of few studies, all clinical and biomechanical studies address cranial segment degeneration following the rigid lumbar/lumbosacral instrumentation [39]. All patients were clinically assessed preoperatively and postoperatively with the SF-36 (physical function domain) and Oswestry Disability Index (ODI) score and the pain magnitude with Visual Analogue Scale (0-10 scale, VAS).…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Interspinous implants are used for motion-preserving stabilization of primarily posterior lumbar spinal pathologies like spinal stenosis or facet joint arthritis [8]. The aims are to unload the facet joints, to restore foraminal height and to provide sufficient stability especially in extension but still allow motion in the treated segment.…”
Section: Introductionmentioning
confidence: 99%