2009
DOI: 10.1007/s12194-009-0079-9
|View full text |Cite
|
Sign up to set email alerts
|

Preliminary investigation of the clinical usefulness of super-high-resolution LCDs with 9 and 15 mega-sub-pixels: observation studies with phantoms

Abstract: Our purpose in this study was to evaluate the preliminary clinical efficacy of soft-copy reading of digital mammography, for a 15-mega-sub-pixel (MsP) and a 9-MsP super-high-resolution liquid-crystal display (SHR-LCD) by use of an independent sub-pixel driving technology. We performed three kinds of phantom observation studies by six radiological technologists. Detectability of a contrast-detail phantom and simulated small objects (SSOs) resembling microcalcifications (MCLs), and shape discrimination ability o… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2011
2011
2022
2022

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 17 publications
0
3
0
Order By: Relevance
“…12 The noisecharacteristic advantages were more remarkable with more reduced magnification, and it should be helpful in the image diagnoses by large-matrix images such as digital mammography, in addition to spatial-resolution improvement, as previously reported. [8][9][10] The advantage would be also appreciated in case that displays with enough resolution are not available.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…12 The noisecharacteristic advantages were more remarkable with more reduced magnification, and it should be helpful in the image diagnoses by large-matrix images such as digital mammography, in addition to spatial-resolution improvement, as previously reported. [8][9][10] The advantage would be also appreciated in case that displays with enough resolution are not available.…”
Section: Discussionmentioning
confidence: 99%
“…Observerperformance studies have reported that ISD contributed to better signal detection of phantom and clinical images owing to improved spatial resolution. [9][10][11] These reports emphasized that high resolutions achieved better signal detection and benefitted clinical image diagnosis; nevertheless, the resolution was improved only in the subpixel direction and the pixel size was asymmetric. There have been few reports on the noisecharacteristic contributions by ISD; therefore, we compared the overall noise characteristics of displayed images on the LCD with and without ISD and demonstrated how ISD affected the noise characteristics.…”
Section: Introductionmentioning
confidence: 99%
“…In independent sub-pixel driving (ISD) technology, aiming at high-resolution displays, three sub-pixels contained in one pixel of the LCD-independent display images, which increase the threefold resolution in the direction of the subpixels, facilitates a faithful image display with less curtailed pixels [1,2]. We investigated the characteristics of ISD technology by applying 15 mega-sub-pixel (15 MsP), 9 mega-sub-pixel (9 MsP), and 6 mega-sub-pixel (6 MsP) LCDs and the visual perception of these by observers to evaluate their usefulness as a method of mammographic image display.…”
Section: Introductionmentioning
confidence: 99%