2010
DOI: 10.1088/0029-5515/50/9/095011
|View full text |Cite
|
Sign up to set email alerts
|

Preliminary results of ELMy H-mode experiments on the HL-2A tokamak

Abstract: Typical ELMy H-mode discharges have been achieved on the HL-2A tokamak with combined auxiliary heating of NBI and ECRH. The minimum power required is about 1.1 MW at a density of 1.6 × 10 19 m −3 and increases with a decrease in density, almost independent of the launching order of the ECRH and NBI heating. The energy loss by each edge localized mode (ELM) burst is estimated to be lower than 3% of the total stored energy. At a frequency of typically 400 Hz, the energy confinement time is only marginally reduce… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
52
0
1

Year Published

2010
2010
2022
2022

Publication Types

Select...
8
1

Relationship

2
7

Authors

Journals

citations
Cited by 68 publications
(54 citation statements)
references
References 41 publications
1
52
0
1
Order By: Relevance
“…Its major and minor radius are R = 1.65 m and a = 0.4 m, respectively, toroidal magnetic field B t = 2.8 T, plasma current I p = 480 kA, line averaged electron density ͑1-8͒ ϫ 10 19 m −3 , edge safety factor q a =3-5, and a discharge duration of ϳ3.0 s. 11 The visible optical diagnostic system for edge turbulence measurement mainly consists of three lenses which are designed to reduce spherical aberration and coma, an interference filter for D ␣ line emission, and a photodiodes detector array which has 46 available channels. The distance between the detectors and the object plane is 110 cm.…”
Section: Methodsmentioning
confidence: 99%
“…Its major and minor radius are R = 1.65 m and a = 0.4 m, respectively, toroidal magnetic field B t = 2.8 T, plasma current I p = 480 kA, line averaged electron density ͑1-8͒ ϫ 10 19 m −3 , edge safety factor q a =3-5, and a discharge duration of ϳ3.0 s. 11 The visible optical diagnostic system for edge turbulence measurement mainly consists of three lenses which are designed to reduce spherical aberration and coma, an interference filter for D ␣ line emission, and a photodiodes detector array which has 46 available channels. The distance between the detectors and the object plane is 110 cm.…”
Section: Methodsmentioning
confidence: 99%
“…The HL-2A tokamak (with major radius R = 1.65 m and minor radius a = 0.4 m) has two rather closed divertor chambers [6,7], however the lower single null (LSN) divertor configuration is used in this experiment. An IR camera which is sensitive to radiation wavelengths between 8 lm and 9 lm, has been developed to measure the evolution of the surface temperature on the outer divertor plates on HL-2A [8,9].…”
Section: Infrared Thermography and Heat Flux Calculationmentioning
confidence: 99%
“…Routine stable H-mode discharge has been realized since 2009. 12 Here, we model the HL-2A discharge to explore the dynamics of ITB development.…”
Section: Modeling Of Spontaneous Itb Development In Hl-2amentioning
confidence: 99%