2020
DOI: 10.1109/tasc.2020.2973119
|View full text |Cite
|
Sign up to set email alerts
|

Preload Characterization of Short Models of MQXF the Nb3Sn Low-β Quadrupole for the Hi-Lumi LHC

Abstract: MQXF is the Nb3Sn Low-β Quadrupole magnet that the HL-LHC project is planning to install in the LHC interaction regions in 2026 as part of an upgrade to increase the LHC integrated luminosity by about a factor of ten. The magnet will be fabricated in two different lengths: 4.2 m for MQXFA, built in the US by the Accelerator Upgrade Project (AUP), and 7.15 m for MQXFB, fabricated by CERN. In order to qualify the magnet design and characterize its performance with different conductors, cable geometries and pre-l… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0

Year Published

2021
2021
2021
2021

Publication Types

Select...
5

Relationship

4
1

Authors

Journals

citations
Cited by 7 publications
(28 citation statements)
references
References 12 publications
0
28
0
Order By: Relevance
“…Thus they deform plastically when tested. The resulting shape resembles the so called dent in [11]: the radius is reduced near the MP whereas the opposite is true near the poles. According to FEM the coils take a similar shape when preloaded.…”
Section: Coil Size Asymmetrymentioning
confidence: 86%
See 3 more Smart Citations
“…Thus they deform plastically when tested. The resulting shape resembles the so called dent in [11]: the radius is reduced near the MP whereas the opposite is true near the poles. According to FEM the coils take a similar shape when preloaded.…”
Section: Coil Size Asymmetrymentioning
confidence: 86%
“…The MP-MP contact takes into account the coil shape on both sides and the MP shims. In [11] it was noted that the coil pack size determined in the TF-KP (transfer function -key plot) analysis yielded on average 100 µm lower value than the value calculated according to the shimming plan. There are two possibilities: 1. the coil is smaller than measured, thus additional 100 µm can be reduced from the coil-collar contact offset, or 2. the structure does not exactly match their design values and thus one can add 100 µm to the loading key size.…”
Section: The Fe Modelmentioning
confidence: 95%
See 2 more Smart Citations
“…The azimuthal solution is in general preferred, as it allows to bring the four coils inner surface at the same radius, with beneficial effects on the field homogeneity [19]. Radially, the target is to have about 125 μm smaller shims in order to improve the coil-collar contact [20]. Figure 8 shows the final shimming lay-out for the two MQXFB Prototype magnets.…”
Section: Magnet Assembly and Loadingmentioning
confidence: 99%