Background
Various factors may be related to outcomes of reverse shoulder arthroplasty (RSA) including patient and surgical factors. Differences in shoulder kinematics might be associated with poor function after RSA; however, kinematic differences between shoulders with good or poor elevation have not been elucidated. The purpose of this study was to compare RSA kinematics between shoulders with good or poor elevation.
Methods
The study included 28 shoulders with a minimum 6-month follow-up after RSA using Grammont-type prostheses. Subjects comprised 17 men and 11 women with the mean age of 75 years (range, 63-91). Subjects underwent fluoroscopy during active scapular plane abduction. Computed tomography of their shoulders was performed to create 3-dimensional scapular implant models. Using model-image registration techniques, poses of 3-dimensional implant models were iteratively adjusted to match their silhouettes with the silhouettes in the fluoroscopic images, and 3-dimensional kinematics of implants were computed. Kinematics and glenosphere orientation were compared between shoulders with good (>90 degree) or poor (<90 degree) scapular plane abduction.
Results
Nineteen and 9 shoulders were assigned to the good- and poor-elevation groups, respectively. There were no significant differences between the groups in age, sex, height, weight, preoperative range of motion, or Constant score, but body mass index in the poor elevation shoulders was significantly larger than that in the good elevation shoulders. There were no significant differences in glenosphere (upward/downward rotation, anterior/posterior tilt, internal/external rotation) or glenohumeral (internal/external rotation, abduction/adduction) kinematics between the good and poor elevation shoulders. Scapulohumeral rhythm was significantly higher in the good elevation shoulders than the poor elevation shoulders (
P
= .04). Glenosphere superior tilt was 2.3° ± 4.2° in the good-elevation group and 8.1° ± 8.9° in the poor-elevation group, and the difference was statistically significant (
P
=Â .03).
Discussion
Shoulders with good elevation after RSA demonstrated better scapulohumeral rhythm than those with poor elevation, though there were no significant differences in glenosphere and glenohumeral kinematics. It may be important for better elevation to achieve good glenohumeral motion in shoulders with RSA. Glenosphere orientations may affect postoperative shoulder function.