“…The chromatographic analysis was performed on a LC‐20AD system (Shimadzu) coupled with an evaporative light scattering detector (Wayeal Corp.). A self‐made PSZ column was used here, as described previously [22]. In addition, two zwitterionic columns were also tested, including a silica‐based sulfobetaine functionalized zwitterionic column (SSZ), prepared by the same grafting method as PSZ, and a polymer‐based ester‐type sulfobetaine functionalized zwitterionic column (PESZ), prepared by the same substrate as PSZ except that ester‐type sulfobetaine monomer was used to replace amide‐type one used in PSZ.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…The chromatographic analysis was performed on a LC‐20AD system (Shimadzu) coupled with an evaporative light scattering detector (Wayeal Corp.). A self‐made PSZ column was used here, as described previously [22]. In addition, two zwitterionic columns were also tested, including a silica‐based sulfobetaine functionalized zwitterionic column (SSZ), prepared by the same grafting method as PSZ, and a polymer‐based ester‐type sulfobetaine functionalized zwitterionic column (PESZ), prepared by the same substrate as PSZ except that ester‐type sulfobetaine monomer was used to replace amide‐type one used in PSZ.…”
Section: Methodsmentioning
confidence: 99%
“…The chromatographic analysis was performed on a LC-20AD system (Shimadzu) coupled with an evaporative light scattering detector (Wayeal Corp.). A self-made PSZ column was used here, as described previously [22].…”
Section: Instrumentationmentioning
confidence: 99%
See 1 more Smart Citation
“…In 1975, the first generation of HILIC mode on the aminosilica phase was used for the separation of saccharides [62]. With the development of HILIC, different types of stationary phases with various ligands emerged in saccharide separation studies, including diol bonded [63][64][65][66], amino-bonded [67,68], amide-bonded [69][70][71][72], and polymer-bonded phases [73,74], etc. Several published experimental cases of the separation of saccharides on different types of stationary phases are listed in Table 1.…”
Section: Hydrophilic Interaction Liquid Chromatographymentioning
confidence: 99%
“…For instance, poly(sulfobetaine), employed as an implant material and device, can reduce protein adsorption and limit cellular adhesion and inflammatory response [ 3 ]. Various sulfobetaine-based packing columns, including commercial zwitterionic hydrophilic interaction liquid chromatography (ZIC-HILIC) [ 5 ], N , N -dimethyl- N -methacryloxyethyl- N -(3-sulfopropyl)ammonium betaine (SPE)- [ 6 ], 3-[2-(acrylamido)-ethyldimethylammonio] propane sulfonate- [ 7 ], and acrylamide-type sulfobetaine-based [ 8 ] stationary phases, have been developed for the separation of polar analytes or enrichment of glycopeptides via hydrophilic or electrostatic interactions [ 9 ]. Although good chromatographic performance was obtained, the preparation process of the packed column was very complicated, which limits its further application [ [10] , [11] , [12] ].…”
Section: Introductionmentioning
confidence: 99%