2016
DOI: 10.1002/cjce.22679
|View full text |Cite
|
Sign up to set email alerts
|

Preparation, characterization, and application of vertically aligned CNT sheets through template assisted pyrolysis of PBI‐Kapton

Abstract: This article investigates the synthesis of vertically aligned carbon nanotube (CNT) sheets through the pyrolysis of polybenzimidazole (PBI)‐Kapton inside the pores of anodized aluminium oxide (AAO). The nanocomposites of CNT/Alumina obtained were characterized by several techniques. It was found that the resulting carbon structures presented higher crystallinity compared with graphite. All of the CNT sheets had high antibacterial activity that was proportional to degree of CNT crystallinity. Moreover, the desa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
5
0

Year Published

2017
2017
2021
2021

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(5 citation statements)
references
References 83 publications
0
5
0
Order By: Relevance
“…In five of these papers, CA is only an inlet parameter in a model or a numerical simulation. The twelve remaining involve experimental measurements, all of which were performed with an optical goniometer or derived instruments . The latter enables analysis at a liquid/liquid/solid or a liquid/gas/solid interface instead of a gas/liquid/solid one (Figure ).…”
Section: Applicationsmentioning
confidence: 99%
See 4 more Smart Citations
“…In five of these papers, CA is only an inlet parameter in a model or a numerical simulation. The twelve remaining involve experimental measurements, all of which were performed with an optical goniometer or derived instruments . The latter enables analysis at a liquid/liquid/solid or a liquid/gas/solid interface instead of a gas/liquid/solid one (Figure ).…”
Section: Applicationsmentioning
confidence: 99%
“…The latter enables analysis at a liquid/liquid/solid or a liquid/gas/solid interface instead of a gas/liquid/solid one (Figure ). Works performed with an optical goniometer mainly employed the static sessile drop method with only two employing dynamic methods . Three studies included qualitative surface analysis through scanning electron microscopy images to estimate the substrate roughness: Ahmmed et al published the only manuscript in which both advancing and receding contact angles are reported and in which an estimation of the hysteresis is provided.…”
Section: Applicationsmentioning
confidence: 99%
See 3 more Smart Citations