2011
DOI: 10.1016/j.jcis.2010.12.018
|View full text |Cite
|
Sign up to set email alerts
|

Preparation of polydiacetylene immobilized optically encoded beads

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
17
0

Year Published

2012
2012
2020
2020

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 13 publications
(17 citation statements)
references
References 33 publications
0
17
0
Order By: Relevance
“…In addition, Raman detection has high selectivity, since molecules have their own Raman fingerprint peaks (Gan et al, 2019). However, such applications of PDAs are still in the infancy, presumably due to the weak Raman signal caused by the small Raman cross sections area of C=C and C=C in PDA (Jun et al, 2011;Kim H.-M. et al, 2015).…”
Section: Pda For Raman Detection and Raman Bioimagingmentioning
confidence: 99%
“…In addition, Raman detection has high selectivity, since molecules have their own Raman fingerprint peaks (Gan et al, 2019). However, such applications of PDAs are still in the infancy, presumably due to the weak Raman signal caused by the small Raman cross sections area of C=C and C=C in PDA (Jun et al, 2011;Kim H.-M. et al, 2015).…”
Section: Pda For Raman Detection and Raman Bioimagingmentioning
confidence: 99%
“…30,65,126,151 However, some label-free patterns have also been developed. 202204 Moreover, various patterns for signal amplification have been developed to increase overall sensitivity. 205209 …”
Section: Optical Label and Signal Amplificationmentioning
confidence: 99%
“…204,235,236 As novel optoelectronic materials, CPs have been widely used in biosensing, bioimaging, therapy, 239243 and barcoding 244 due to their high fluorescence quantum yields and large extinction coefficients. Jun et al 204 coated a polydiacetylene (PDA, a water-soluble fluorescent conjugated polymer 241 ) layer onto optically-encoded microspheres, with the PDA layer exhibiting a blue to red color change induced by external stress. However, color change of the PDA can be induced not only by antibody-antigen binding but also by other stressors, including pH and temperature, thus limiting their practical application for high-throughput, multiplexing of targets.…”
Section: Optical Label and Signal Amplificationmentioning
confidence: 99%
“…Recently, we combined aptamer-based molecular beacons (MBs) [37] or polydiacetylene (PDA) [60] with optically-beads, which can be used with a bead-based array system. The system is designed to generate fluorescence by binding event as shown in Figure 3b, and offers the additional advantage of separation by target protein amount using flow cytometry.…”
Section: Fluorescence-encoded Beads For Protein Detectionmentioning
confidence: 99%