2002
DOI: 10.1016/s0140-6736(02)09599-5
|View full text |Cite
|
Sign up to set email alerts
|

Prevalence, incidence, and mother-to-child transmission of HIV-1 in rural South Africa

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

2
29
1

Year Published

2006
2006
2015
2015

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 50 publications
(32 citation statements)
references
References 4 publications
2
29
1
Order By: Relevance
“…If HIV-specific antibodies were detected, the same dried blood spot sample was then tested for HIV DNA using a commercial PCR-based assay (HIV-1 DNA Amplicor version 1.5, Roche Diagnostics, Pleasanton, United States of America). 10 HIV testing was anonymous: enrolled infants were each assigned a unique study number at enrolment, no identifying information was collected, and HIV results were added to the database after completion of the study. Linked non-anonymous HIV counselling and testing were, however, provided for the child of any caregiver who wished to receive the results of his or her child's HIV test.…”
Section: Hiv Testingmentioning
confidence: 99%
“…If HIV-specific antibodies were detected, the same dried blood spot sample was then tested for HIV DNA using a commercial PCR-based assay (HIV-1 DNA Amplicor version 1.5, Roche Diagnostics, Pleasanton, United States of America). 10 HIV testing was anonymous: enrolled infants were each assigned a unique study number at enrolment, no identifying information was collected, and HIV results were added to the database after completion of the study. Linked non-anonymous HIV counselling and testing were, however, provided for the child of any caregiver who wished to receive the results of his or her child's HIV test.…”
Section: Hiv Testingmentioning
confidence: 99%
“…Furthermore extensive studies proved that concerns about the presence of haem in the eluate and adverse storage, for example in tropical conditions, causing false reactions were unfounded 3,17,25 . DBS has been used in large scale HIV surveillance studies for over a decade 16,26 .…”
Section: Introductionmentioning
confidence: 99%
“…DBS samples serve as suitable practical samples for quality EID in multiple countries (16)(17)(18)(19)(20)(21). To help Ukraine expand its EID services and to increase infants' and children's access to EID in resource-limited settings or remote areas, the performance of Ukraine's EID test, i.e., the AmpliSens assay, as well as the Roche CAP/CTM Qual and Abbott Qualitative assays, was evaluated by using DBS samples from HIV-exposed Ukrainian infants or children; those results were compared with the performance of Ukrainian EID testing using venous whole-blood samples.…”
Section: Discussionmentioning
confidence: 99%
“…Because of their greater stability at ambient temperature, DBS samples can be transported by postal mail to centralized laboratories for testing and, if packaged correctly, do not raise biosafety concerns regarding the health of postal workers (9)(10)(11)(12)(13)(14)(15). Published data indicate that DBS samples are suitable and practical for quality EID and have aided service expansion in sub-Saharan Africa (16)(17)(18)(19)(20)(21). In our study, for the first time, the performances of the AmpliSens DNA PCR assay and two commercially of Science, Central Research Institute for Epidemiology, Moscow, Russia) instruction manual (28).…”
mentioning
confidence: 99%