2017
DOI: 10.1002/9781119407461
|View full text |Cite
|
Sign up to set email alerts
|

Process Control Design for Industrial Applications

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
14
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
4
2
1

Relationship

1
6

Authors

Journals

citations
Cited by 15 publications
(14 citation statements)
references
References 0 publications
0
14
0
Order By: Relevance
“…According to [15], there are two approaches for using fuzzy logic to make a decision: the conventional approach, in which the defuzzification process is carried out at an early stage and a fuzzy approach in which defuzzification is accomplished in the final stages. In Figure 2, the most simplified diagram of a fuzzy logic system is depicted [30][31][32]. In this diagram, the fuzzification block converts the distinct input values into a fuzzy dataset (regarding temperature, values such as −10 °C and 15 °C are converted to "cold" and "warm").…”
Section: Fuzzy Logic Principalsmentioning
confidence: 99%
“…According to [15], there are two approaches for using fuzzy logic to make a decision: the conventional approach, in which the defuzzification process is carried out at an early stage and a fuzzy approach in which defuzzification is accomplished in the final stages. In Figure 2, the most simplified diagram of a fuzzy logic system is depicted [30][31][32]. In this diagram, the fuzzification block converts the distinct input values into a fuzzy dataset (regarding temperature, values such as −10 °C and 15 °C are converted to "cold" and "warm").…”
Section: Fuzzy Logic Principalsmentioning
confidence: 99%
“…Furthermore, we have considered a control structure which involves three closed loops, presented in Figure 1: FRC-1, control loop for steam/ethane flow ratio; TRC-2, control loop for temperature; PRC-3 control loop for pressure. For the control solution, RST polynomial control was recommended to assure the construction of the two-level proposed architecture, offering independent performances in tracking and control [12,[17][18][19].…”
Section: Nominal Control Level Designmentioning
confidence: 99%
“…Since steam flow respects the ratio imposed with ethane flow, it is thus achieved the control of both parameters. In order to determine the control algorithm for the steam flow which is pumped into the reactor, we have analytically determined the mathematical model based on the flow equations provided by the parameters of the technological pipe, from the experimental platform [18,19].…”
Section: Control Of Stream/ethane Flow Ratiomentioning
confidence: 99%
See 2 more Smart Citations