Progress in the development of a fluorescent intravascular blood gas system in man

Abstract: In vitro and in vivo animal studies have shown accurate measurements of arterial blood pH (pHa), carbon dioxide tension (PaCO2), and oxygen tension (PaO2) with small intravascular fluorescent probes. Initial human clinical studies showed unexplained intermittent large drops in sensor oxygen tension (PiO2). Normal volunteers were studied to elucidate this problem. In the first part of this study, the probe and cannula were manipulated and the probe configuration and its position within the cannula were varied. … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
30
0
1

Year Published

1992
1992
2006
2006

Publication Types

Select...
4
3
1

Relationship

0
8

Authors

Journals

citations
Cited by 71 publications
(31 citation statements)
references
References 19 publications
0
30
0
1
Order By: Relevance
“…In addition to the advantages of in situ monitoring under near real-time conditions, problems with discrete arterial blood sampling, such as, systematic errors due to air bubbles (Biswas et al 1982;Harsten et al 1988;Thorson et al 1983), dilution from flush solution (Boidin andJorna, 1984;Hamilton et al 1978), storage temperature, or time delay between sampling and measurement (Kelman and Nunn 1966) were avoided using fiber-optic biosensor technology. The biosensor technology described in this report utilized phosphorescence; however, alternative technological approaches using fluorescence or micro electrodes also have been developed for fiber-optic biosensors (Barker and Hyatt 1991;Mahutte et al 1990;Shapiro 1992;Shapiro et al 1989) and could be similarly applied.…”
Section: Discussionmentioning
confidence: 99%
“…In addition to the advantages of in situ monitoring under near real-time conditions, problems with discrete arterial blood sampling, such as, systematic errors due to air bubbles (Biswas et al 1982;Harsten et al 1988;Thorson et al 1983), dilution from flush solution (Boidin andJorna, 1984;Hamilton et al 1978), storage temperature, or time delay between sampling and measurement (Kelman and Nunn 1966) were avoided using fiber-optic biosensor technology. The biosensor technology described in this report utilized phosphorescence; however, alternative technological approaches using fluorescence or micro electrodes also have been developed for fiber-optic biosensors (Barker and Hyatt 1991;Mahutte et al 1990;Shapiro 1992;Shapiro et al 1989) and could be similarly applied.…”
Section: Discussionmentioning
confidence: 99%
“…The differences in pO 2 measurements between continuous and intermittent analyses appeared to be somewhat higher in our study (1.0 kPa) than in previous results (up to 0.78 kPa). One possible explanation may be a phenomenon called the 'wall effect' (Mahutte et al 1990) which occurs when the sensor has direct contact with the vascular wall and cannot oat freely. In this case, the measured value represents the gas tension from the blood as well as in the tissue surrounding the artery.…”
Section: Continuous Blood Gas Monitoring In Rats 135mentioning
confidence: 99%
“…These include measurement of dissolved CO 2 in blood (30,31) and measurements of CO 2 as a predictor for shock (32,33). Measurements of CO 2 are also used …”
Section: Discussionmentioning
confidence: 99%