2005
DOI: 10.1039/b504468e
|View full text |Cite
|
Sign up to set email alerts
|

Pumping of mammalian cells with a nozzle-diffuser micropump

Abstract: We discuss the successful transport of jurkat cells and 5D10 hybridoma cells using a reciprocating micropump with nozzle-diffuser elements. The effect of the pumping action on cell viability and proliferation, as well as on the damaging of cellular membranes is quantified using four types of well-established biological tests: a trypan blue solution, the tetrazolium salt WST-1 reagent, the LDH cytotoxicity assay and the calcium imaging ATP test. The high viability levels obtained after pumping, even for the mos… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
24
0

Year Published

2007
2007
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 31 publications
(24 citation statements)
references
References 18 publications
0
24
0
Order By: Relevance
“…The rapid manufacturing of various microchips with different structures and functions is needed by biologists for observations of different kinds of microorganisms [54][55][56][57]. Meanwhile, micromechanical components such as a microvalve can be integrated in the microfluidics as described above [19].…”
Section: De Nition Of Nanoaquariummentioning
confidence: 99%
“…The rapid manufacturing of various microchips with different structures and functions is needed by biologists for observations of different kinds of microorganisms [54][55][56][57]. Meanwhile, micromechanical components such as a microvalve can be integrated in the microfluidics as described above [19].…”
Section: De Nition Of Nanoaquariummentioning
confidence: 99%
“…For the precise measurement of the pumping volume, we connected the microtube (inner diameter: 508 μm) at the outlet and measured the distance that the media was moved by the pumping system. Yamahata et al (2005) examined the effect of pulsatile pumping (with nozzle-diffuser micropump) on jurkat cells and 5D10 hybridoma cells. Similarly, we investigated whether the pumping frequency and the pneumatic pumping pressure might affect the cells during delivery to the culture chamber.…”
Section: Measurement Of Pumping Performance and Pumping Effect On Thementioning
confidence: 99%
“…Another advantage of our technique based on laser direct writing is that a wide variety of structures can be fabricated by the same procedure with little difficulty, namely, it is suitable for rapid manufacturing. The rapid manufacturing of various microchips with different structures is desired by biologists for the observation of different kinds of cells and microorganisms (Yamahata et al 2005;Choi et al 2007;Haeberle and Zengerle 2007;Funfak et al 2007). In the meanwhile, micromechanical components such as a microvalve can be integrated in the microfluidics ).…”
Section: Introductionmentioning
confidence: 98%