2022
DOI: 10.3390/inorganics10070093
|View full text |Cite
|
Sign up to set email alerts
|

Purification and Characterization of High Purity Nano Zirconia by Liquid-Liquid Extraction Using D2EHPA/p-Xylenes

Abstract: In this paper, Zr(IV) nitrate solution decomposed from Viet Nam zircon concentrate was the source of zirconium extraction by liquid-liquid extraction (L.L.E). The FT-IR and UV-Vis spectra confirmed the extraction of Zr(IV) by D2EHPA/p-xylenes. There were four stages for the purification of impurities from the Zr matrix. First, the extraction of elements in 3.0 M HNO3 by 50% D2EHPA/p-xylenes was conducted. Second, two scrubbing cycles of impurities using 6.0 M HNO3, 76.5% of the total amount of Zr(IV) were reta… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

2
0
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 39 publications
(61 reference statements)
2
0
0
Order By: Relevance
“…Other prominent monoclinic zirconia peaks occurred at 2θ angles 28.1, 35.6, 39.8, 45.6, 49.6, 54.2, 55.3, 57.0, 60.2, 68.1, 74.0, and 76.5 in conformity with reported data [73][74][75]. Te peaks at 2θ 20.06 °and 28.96 °are attributable to calcium alginate [75,76]. Most of the important peaks of ZAB-1 and ZAB-2 are in agreement with those of ZrO 2 with the dominant monoclinic phase [77][78][79].…”
Section: Characterization Of Hydrated Zirconium Oxide-coatedsupporting
confidence: 91%
See 1 more Smart Citation
“…Other prominent monoclinic zirconia peaks occurred at 2θ angles 28.1, 35.6, 39.8, 45.6, 49.6, 54.2, 55.3, 57.0, 60.2, 68.1, 74.0, and 76.5 in conformity with reported data [73][74][75]. Te peaks at 2θ 20.06 °and 28.96 °are attributable to calcium alginate [75,76]. Most of the important peaks of ZAB-1 and ZAB-2 are in agreement with those of ZrO 2 with the dominant monoclinic phase [77][78][79].…”
Section: Characterization Of Hydrated Zirconium Oxide-coatedsupporting
confidence: 91%
“…Te characteristic XRD difraction peak of the monoclinic zirconia phase appeared at 28.1 °and there was an absence of a tetragonal zirconia difraction peak at 30 °, suggesting an almost monoclinic nature [71,72]. Other prominent monoclinic zirconia peaks occurred at 2θ angles 28.1, 35.6, 39.8, 45.6, 49.6, 54.2, 55.3, 57.0, 60.2, 68.1, 74.0, and 76.5 in conformity with reported data [73][74][75]. Te peaks at 2θ 20.06 °and 28.96 °are attributable to calcium alginate [75,76].…”
Section: Characterization Of Hydrated Zirconium Oxide-coatedsupporting
confidence: 89%