2013
DOI: 10.1109/jphotov.2013.2271191
|View full text |Cite
|
Sign up to set email alerts
|

PV Module Parameter Characterization From the Transient Charge of an External Capacitor

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
29
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
7
1

Relationship

2
6

Authors

Journals

citations
Cited by 43 publications
(29 citation statements)
references
References 10 publications
0
29
0
Order By: Relevance
“…Fig. 3 shows the classical single-exponential model of a solar cell (Spertino et al, 2013) which supplies a capacitor modelled as the parallel of the capacitance (C) and the isolation resistance (R C ). An output current equation of the solar cell can be written as:…”
Section: The Transient Charging Of a Capacitor Supplied By A Pv Genermentioning
confidence: 99%
See 2 more Smart Citations
“…Fig. 3 shows the classical single-exponential model of a solar cell (Spertino et al, 2013) which supplies a capacitor modelled as the parallel of the capacitance (C) and the isolation resistance (R C ). An output current equation of the solar cell can be written as:…”
Section: The Transient Charging Of a Capacitor Supplied By A Pv Genermentioning
confidence: 99%
“…Nevertheless, when a PV generator is made of the parallel connection of strings and the strings are made of the series connection of PV modules (normally, a group of cells in series), the parasitic capacitance (junction and ground coupling) and leakage inductance are required (Spertino et al, 2013) to understand the behavior of the equivalent circuit in Fig. 3.…”
Section: The Transient Charging Of a Capacitor Supplied By A Pv Genermentioning
confidence: 99%
See 1 more Smart Citation
“…2016, 6, 261 2 of 17 suitable for low power application [11]. Most of the MPPT techniques require the panel parameter values [12] and are based on both measurements of PV current and voltage. Another important aspect is regarding the priority consumption of the green energy production versus traditional production from fossil energy sources, which is also pursued by means of fault-tolerant converters [13].…”
Section: Description Of the Systemmentioning
confidence: 99%
“…The automatic data acquisition system, described in [6], is periodically calibrated and is made of: The I-V curves of a PV array was measured with a capacitive load, detecting simultaneously voltage, current, irradiance and temperature [16], [17]. The next data-processing to achieve the Standard Test Conditions (STC, G=1 kW/m 2 , T c =25 °C) parameters is performed by a conventional correction method [18].…”
Section: Measurements Of I-v Curves On Pv Arraysmentioning