Qualitative Evaluation of Fiducial Markers for Radiotherapy Imaging

Abstract: Purpose To evaluate visibility, artifacts, and distortions of various commercial markers in magnetic resonance imaging (MRI), computer tomography (CT), and ultrasound imaging used for radiotherapy planning and treatment guidance. Methods We compare 2 solid gold markers, 4 gold coils, and 1 polymer marker from 3 vendors. Imaging modalities used were 3-T and 1.5-T GE MRIs, Siemens Sequoia 512 Ultrasound, Phillips Big Bore CT, Varian Trilogy linear accelerator (cone-beam CT [CBCT], on-board imager kilovoltage [… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
59
0

Year Published

2016
2016
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 49 publications
(61 citation statements)
references
References 24 publications
1
59
0
Order By: Relevance
“…The fiducial markers are introduced in the prostate in order to improve the accuracy of EBRT. They facilitate the localization of the prostate, enable motion and deformation tracking and act as reference points for distance measurements as well as for registering images obtained from different imaging modalities . Typically 3 radio‐opaque markers are implanted in the prostate before the patient undergoes EBRT planning and remain permanently in the prostate after the completion of the treatment .…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…The fiducial markers are introduced in the prostate in order to improve the accuracy of EBRT. They facilitate the localization of the prostate, enable motion and deformation tracking and act as reference points for distance measurements as well as for registering images obtained from different imaging modalities . Typically 3 radio‐opaque markers are implanted in the prostate before the patient undergoes EBRT planning and remain permanently in the prostate after the completion of the treatment .…”
Section: Introductionmentioning
confidence: 99%
“…They facilitate the localization of the prostate, enable motion and deformation tracking and act as reference points for distance measurements as well as for registering images obtained from different imaging modalities. 30,31,34,35 Typically 3 radio-opaque markers are implanted in the prostate before the patient undergoes EBRT planning and remain permanently in the prostate after the completion of the treatment. 36,37 The markers are placed within the prostate gland using a transperineal or transrectal approach with a needle holding one or two markers, under the guidance of transrectal ultrasound (TRUS) in a procedure similar to that of a biopsy.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…5 and 6), no significant dose shadow effect seems to appear. Finally, all OrthoCT images deemed useful have shown no artifacts whatsoever, which is a remarkable advantage in respect to other imaging techniques utilized in concomitance with FMs [21].…”
Section: Discussionmentioning
confidence: 79%
“…The precision of radiotherapy for prostate cancer has been improving, and intensity-modulated radiotherapy (IMRT) is commonly performed using fiducial markers [1][2][3], because the treatment is repeated and markers capable of being depicted on magnetic resonance imaging (MRI) are necessary. However, there are many fiducial markers in the world and they can sometimes be difficult to recognize on MR.…”
Section: Introductionmentioning
confidence: 99%