2015
DOI: 10.1016/j.jfo.2014.10.018
|View full text |Cite
|
Sign up to set email alerts
|

Qualité de vie des patients équipés en verres scléraux

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
12
1

Year Published

2017
2017
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(16 citation statements)
references
References 7 publications
1
12
1
Order By: Relevance
“…C-ScCLs and ScCLs are not usually the first choice to fit but are commonly prescribed when other CLs (SCLs, RGPCLs, PBCLs [ 94 ], and HCLs [ 106 , 107 , 112 , 113 ]) show tolerance problems [ 117 , 118 ] or do not provide acceptable VA. [ 48 50 , 118 – 121 ].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…C-ScCLs and ScCLs are not usually the first choice to fit but are commonly prescribed when other CLs (SCLs, RGPCLs, PBCLs [ 94 ], and HCLs [ 106 , 107 , 112 , 113 ]) show tolerance problems [ 117 , 118 ] or do not provide acceptable VA. [ 48 50 , 118 – 121 ].…”
Section: Resultsmentioning
confidence: 99%
“…Patients with KC have shown an 88% improvement in visual acuity postscleral lens fitting [ 120 ]. In an observational retrospective study, Picot et al [ 118 ] evaluated the contribution of scleral lenses in terms of improving the quality of life in the treatment of astigmatism after penetrating keratoplasty and keratoconus. In this study, VA progressed from 0.68 ± 0.46 to 0.15 ± 0.17 logMAR at the 6th month after ScCL fitting in the better eye.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…16 Our study showed that initial VA of 0.6160.56 logMAR (0.2460.27 on the decimal scale) improved to 0.1460.19 logMAR (0.7260.64 on the decimal scale), a mean increase of 5 lines. Picot et al 20 reported similar findings; initial VA was 0.6860.46 logMAR (0.2160.35 on the decimal scale) and improved to 0.1560.17 logMAR (0.7160.68 on the decimal scale), a mean increase of four lines with scleral lenses. Similar studies of large scleral lenses for irregular corneas have shown comparable increases in VA. 14,22 Recently, Macedo-de-Araújo et al 10 reported that low-and high-contrast visual acuities improved after scleral lens fitting, allowing an increase of two or more logMAR lines ($0.2 logMAR) with respect to best spectacle correction.…”
Section: Population and Visual Acuitymentioning
confidence: 60%
“…Scleral lenses are often reserved for advanced cases. Current scleral lenses offer good visual performance and comfort [ 26 ].…”
Section: Current Treatment Options and Managementmentioning
confidence: 99%