Quantification of regurgitation in mitral valve prolapse with automated real time echocardiographic 3D proximal isovelocity surface area: multimodality consistency and role of eccentricity index

Abstract: Three-dimensional transthoracic echocardiography (3D-TTE) provides a semi-automated proximal isovelocity surface area method (3D-PISA) to obtain quantitative parameters. Data assessing regurgitation severity in mitral valve prolapse (MVP) are scarce, so we assessed the 3D-PISA method compared with 2D-PISA and cardiovascular magnetic resonance (CMR) and the role of an eccentricity index. We evaluated the 3D-PISA method for assessing MR in 54 patients with MVP (57 ± 14 years; 42 men; 12 mild/mild-moderate; 12 mo… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
3
0
1

Year Published

2023
2023
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 20 publications
0
3
0
1
Order By: Relevance
“…The first consists in measurement of the 3D surface of the proximal flow convergence region without any geometric assumption ( 74 ). Spampinato et al prospectively evaluated the diagnostic accuracy of the 3D PISA method in comparison to standard 2D echocardiography, and cardiac magnetic resonance, using a multiparametric 2D TTE approach as reference for assessing the MR grade in a population of MVP patients ( 80 ). They showed that semi-automated RT 3DE derived PISA may allow similar MR grading as compared to standard 2D TTE, with overestimation in case of asymmetric flow convergence zone or when assuming cardiac magnetic resonance as reference ( 80 ).…”
Section: Clinical Applications Of 3d Echocardiography In the Study Of...mentioning
confidence: 99%
See 2 more Smart Citations
“…The first consists in measurement of the 3D surface of the proximal flow convergence region without any geometric assumption ( 74 ). Spampinato et al prospectively evaluated the diagnostic accuracy of the 3D PISA method in comparison to standard 2D echocardiography, and cardiac magnetic resonance, using a multiparametric 2D TTE approach as reference for assessing the MR grade in a population of MVP patients ( 80 ). They showed that semi-automated RT 3DE derived PISA may allow similar MR grading as compared to standard 2D TTE, with overestimation in case of asymmetric flow convergence zone or when assuming cardiac magnetic resonance as reference ( 80 ).…”
Section: Clinical Applications Of 3d Echocardiography In the Study Of...mentioning
confidence: 99%
“…Spampinato et al prospectively evaluated the diagnostic accuracy of the 3D PISA method in comparison to standard 2D echocardiography, and cardiac magnetic resonance, using a multiparametric 2D TTE approach as reference for assessing the MR grade in a population of MVP patients ( 80 ). They showed that semi-automated RT 3DE derived PISA may allow similar MR grading as compared to standard 2D TTE, with overestimation in case of asymmetric flow convergence zone or when assuming cardiac magnetic resonance as reference ( 80 ). The authors argued that 3D PISA has the advantage to display the localization and extension of the proximal flow convergence region from the “en-face” view, aiding the observer in the evaluation of MVP complexity ( 80 ).…”
Section: Clinical Applications Of 3d Echocardiography In the Study Of...mentioning
confidence: 99%
See 1 more Smart Citation
“…У данного метода есть ограничения, например из-за того, что регургитационное отверстие может быть не совсем круглым, а следовательно, проксимальная изоскоростная зона получается не совсем идеальной полусферой. Но это преодолимо, например с помощью 3-d эхокардиографии [11]. Для оценки тяжести АР имеет также значение vena contracta, самый узкий участок струи из аорты в выходной тракт левого желудочка.…”
Section: гемодинамика регургитационной струиunclassified