2008
DOI: 10.1016/j.wear.2007.12.008
|View full text |Cite
|
Sign up to set email alerts
|

Quantification of UHMWPE wear in periprosthetic tissues of hip arthroplasty: Description of a new method based on IR and comparison with radiographic appearance

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
15
0
8

Year Published

2008
2008
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 25 publications
(23 citation statements)
references
References 20 publications
0
15
0
8
Order By: Relevance
“…In 25 cases we correlated total amounts of wear particles with osteolysis in various zones around TJR [13], while the remaining results are being pro- Table 2); error bars were calculated as estimated standard deviations of the corresponding average. The columns are given in quadruplets; the columns in each quadruplet, from left to right, correspond to flotation, centrifugation at 500 × g, 16,000 × g and 105,000 × g, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…In 25 cases we correlated total amounts of wear particles with osteolysis in various zones around TJR [13], while the remaining results are being pro- Table 2); error bars were calculated as estimated standard deviations of the corresponding average. The columns are given in quadruplets; the columns in each quadruplet, from left to right, correspond to flotation, centrifugation at 500 × g, 16,000 × g and 105,000 × g, respectively.…”
Section: Resultsmentioning
confidence: 99%
“…Firstly, we used a well-established isolation technique, which had already been employed and perfected in our previous studies [12][13][14][15]. Secondly, the purity of the isolated PE particles on PC membranes was investigated by means of FTIR: comparison of IR spectra of pure PE, unused PC membrane and PC membrane with PE nanoparticles showed that all samples exhibited only peaks of PE and/or PC (Fig.…”
Section: Purity Of Isolated Particlesmentioning
confidence: 99%
“…[11][12][13][14][15][16][17][18][19][20]). Particles coming from one of our typical samples of periprosthetic tissue are shown in Fig.…”
Section: Nanoparticles In Other Samplesmentioning
confidence: 99%
See 1 more Smart Citation
“…In most published studies the particle shapes and sizes are determined indirectly via size fractionation using filtration and imaging of the filter surface with scanning electron microscopy (SEM) [9][10][11][12][13][14]. Fractionated abundance distributions are often obtained by counting particles in characteristic SEM images.…”
Section: Introductionmentioning