Quantitative analysis of chlorofluorocarbons

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
2

Year Published

1982
1982
1997
1997

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 15 publications
(4 citation statements)
references
References 28 publications
0
2
2
Order By: Relevance
“…The HFC mass detection limits are considerably higher, 14 and 45 ng for HFC-125 and -134a, respectively. These results are worse than those of Vidal-Madjar et al 40 Their ECD mass detection limits for CFC-11 are 75 fg in pulsed detector mode, 250 ft in dc mode, corrected for a SNR of 3. A mass detection limit for CFC-12 of 1.6 pg for dc detector mode is estimated based on their data.…”
Section: Discussioncontrasting
confidence: 67%
“…The HFC mass detection limits are considerably higher, 14 and 45 ng for HFC-125 and -134a, respectively. These results are worse than those of Vidal-Madjar et al 40 Their ECD mass detection limits for CFC-11 are 75 fg in pulsed detector mode, 250 ft in dc mode, corrected for a SNR of 3. A mass detection limit for CFC-12 of 1.6 pg for dc detector mode is estimated based on their data.…”
Section: Discussioncontrasting
confidence: 67%
“…Such results are in contrast, however, with some welldocumented examples of hypercoulometric response (4)(5)(6)(7), observed for different strong electrophores in a pulsed e.c.d. and with the fact that some halocarbons (possibly the many compounds following mechanism ß in the classification of Wentworth and Chen) are especially likely to give nonlinear 1 Present address: Istituto sull' Inquinamento Atmosférico del C.N.R., Area della Ricerca di Roma, C.P.…”
contrasting
confidence: 85%
“…Such measurements are useful to determine the rates of rapid processes associated with heterogeneous electron transfer (3-8). In a previous paper, we demonstrated that the scan rate employed in the cyclic voltammetry technique could be extended to values as high as 500 kV s_1 (9). These voltammograms were, however, distorted by the combined effects of ohmic drop, cell time constant, and instrument response.…”
Section: Resultsmentioning
confidence: 99%
“…Vejrosta and Novak (7) described a dynamic system for producing parts-per-billion levels of such compounds by two-stage dilution of a pure gas stream saturated with the compound of interest. Other workers reported the use of permeation tubes with gravimetricaly calibrated permeation rates to produce accurate concentrations of single organic species (8,9).…”
mentioning
confidence: 99%