2000
DOI: 10.1002/(sici)1096-9071(200004)60:4<455::aid-jmv14>3.0.co;2-q
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative analysis of cytomegalovirus load using a real-time PCR assay

Abstract: A novel real-time PCR assay system was developed to quantify the cytomegalovirus (CMV) genome load. The real-time PCR assay could detect from 6 to over 10(6) copies of CMV-DNA with a wide linear range. The virus load of immunocompromised patients with symptomatic CMV infections was quantified and compared to that of asymptomatic ones. In symptomatic patients, all 17 peripheral blood leukocytes were positive for CMV DNA, and its mean value was 10(3.3) copies/10(6) cells. On the other hand, only 9 of 38 samples … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

11
133
1
1

Year Published

2001
2001
2016
2016

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 163 publications
(146 citation statements)
references
References 31 publications
11
133
1
1
Order By: Relevance
“…13 Real-time PCR was performed using a TaqMan PCR Kit and Model 7700 Sequence Detector (Applied Biosystems, Foster City, CA, USA), as described previously. 9,14,15 The detection limit of this assay was 100 copies ml -1 .…”
Section: Serologymentioning
confidence: 91%
“…13 Real-time PCR was performed using a TaqMan PCR Kit and Model 7700 Sequence Detector (Applied Biosystems, Foster City, CA, USA), as described previously. 9,14,15 The detection limit of this assay was 100 copies ml -1 .…”
Section: Serologymentioning
confidence: 91%
“…The viral loads were normalized to 10 000 human genomic equivalents obtained by quantification of the albumin gene. 25 Normalized viral load above 100 was considered clinically significant and preemptive therapy with ganciclovir was initiated. Patients were treated with i.v.…”
Section: Patients and Healthy Donorsmentioning
confidence: 99%
“…12,13 US17-PCR was performed in Otsuka Assay Laboratories (Otsuka Pharmaceutical, Tokyo, Japan) and IE-PCR was performed in SRL (Tokyo, Japan). Briefly, DNA extracted from 100 l of plasma was subjected to PCR using TaqMan Universal PCR Master Mix (PE Biosystems, Foster City, CA, USA) and the PCR product was detected as an increase in the fluorescent intensity using ABI Prism 7700 (PE Biosystems).…”
Section: Real-time Pcr Assaymentioning
confidence: 99%
“…10 Although it might be too sensitive for discrimination of high-risk patients for CMV disease, 11 the development of real-time PCR has made it possible to quantitatively evaluate the virus load. [12][13][14] However, the threshold of the virus load to discriminate high-risk patients has not been determined, although the threshold of the antigenemia value has been reported. 15,16 Serially monitoring the virus load without administering ganciclovir is the only method to address this issue, but it is unethical.…”
mentioning