2008
DOI: 10.1002/ffj.1905
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative analysis of essential oils: a complex task

Abstract: This article provides a critical overview of current methods to quantify essential oil components. The fields of application and limits of the most popular approaches, in particular relative percentage abundance, normalized percentage abundance, concentration and true amount determination via calibration curves, are discussed in detail. A specific paragraph is dedicated to the correct use of the most widely used detectors and to analyte response factors. A set of applications for each approach is also included… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
113
0
2

Year Published

2009
2009
2020
2020

Publication Types

Select...
6
3

Relationship

1
8

Authors

Journals

citations
Cited by 176 publications
(118 citation statements)
references
References 9 publications
3
113
0
2
Order By: Relevance
“…Actual response factors were measured for two major compounds that were commercially available, (E)-caryophyllene and a-humulene. [22,23] GC-MS analyses were performed on an Agilent 5975 inert N mass selective detector coupled to an Agilent 6890N GC system (Palo Alto, CA, USA). Two types of fused silica capillary column with diff erent polarities were used: a DB-Wax column (60 m × 0.25 mm i.d., fi lm thickness 0.25 µm; J&W Scientifi c) and a DB-5MS column (30 m × 0.25 mm i.d., fi lm thickness 0.25 µm; J&W Scientifi c).…”
Section: Extraction Of Volatile Compoundsmentioning
confidence: 99%
“…Actual response factors were measured for two major compounds that were commercially available, (E)-caryophyllene and a-humulene. [22,23] GC-MS analyses were performed on an Agilent 5975 inert N mass selective detector coupled to an Agilent 6890N GC system (Palo Alto, CA, USA). Two types of fused silica capillary column with diff erent polarities were used: a DB-Wax column (60 m × 0.25 mm i.d., fi lm thickness 0.25 µm; J&W Scientifi c) and a DB-5MS column (30 m × 0.25 mm i.d., fi lm thickness 0.25 µm; J&W Scientifi c).…”
Section: Extraction Of Volatile Compoundsmentioning
confidence: 99%
“…Today, GC is the most commonly used method in this fi eld, advanced and highly sophisticated, with enantioselective capillary columns and coupled with mass spectroscopy (MS) or mass selective detectors (MSDs). [3] Headspace sampling and solid-phase microextraction (HS-SPME), in addition, enables the analysis of even the content of single oil glands, ducts or cavities, showing, for example, that the chemical composition diff ers between leaf insertions and leaf regions and also between the peltate and capitate oil glands of Salvia spp. [4,5] much more than in oregano [6] or peppermint.…”
Section: Development Of Analytical Methodsmentioning
confidence: 99%
“…[4,5] much more than in oregano [6] or peppermint. [7] This indicates the necessity of following the defi nition of EOs [3] and that defi ned random sampling is one of the basic preconditions to obtain comparable and reproducible analytical results. …”
mentioning
confidence: 99%
“…Публикации по теории газохроматографического анализа природных летучих фракций в большей мере сосредоточены в химических, медицинских журна-лах [9,10]. В меньшей мере изучение носителей аро-мата, особенно природного происхождения представ-лено в журналах пищевой науки.…”
Section: анализ литературных данных и постановка проблемыunclassified