2001
DOI: 10.2355/isijinternational.41.757
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative Analysis of Total and Insoluble Elements and Inclusion Composition in Metal by Laser Ablation ICP-MS Method.

Abstract: The development of a rapid and accurate method for determining soluble and insoluble contents of elements and inclusion composition is indispensable to the quality control of steels. The laser ablation-inductively coupled plasma mass spectrometry (LA-ICP-MS) has been successfully applied to the direct analysis of steel composition [1][2][3][4][5][6] and to the determination of trace element concentrations in geological minerals and rocks. [7][8][9][10][11][12] The LA-ICP-MS technique is characterized by the qu… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
30
0

Year Published

2002
2002
2020
2020

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 13 publications
(30 citation statements)
references
References 12 publications
0
30
0
Order By: Relevance
“…The precision and accuracy of the LA-ICP-MS analysis is found to be 2 to 5 % for Al 2 O 3 , MgO and CaO content in synthetic particles of CaO-Al 2 O 3 , CaO-Al 2 O 3 -MgO and MgO-Al 2 O 3 systems. 1,2) The difference between the size of synthetic particles in the range of 10Յd V Յ40 mm obtained by LA-ICP-MS and that by SEM is on the average 1.7 mm by using Al 2 O 3 calibration line and 2.4 mm by using MgO calibration line. 3) In this study, the LA-ICP-MS has been used for the determination of the inclusion composition and size distribution of oxide particles with d V Ͻ10 mm in an Fe-10mass%Ni alloy deoxidized by Al followed by Mg and Mg followed by Al addition.…”
Section: Introductionmentioning
confidence: 99%
See 4 more Smart Citations
“…The precision and accuracy of the LA-ICP-MS analysis is found to be 2 to 5 % for Al 2 O 3 , MgO and CaO content in synthetic particles of CaO-Al 2 O 3 , CaO-Al 2 O 3 -MgO and MgO-Al 2 O 3 systems. 1,2) The difference between the size of synthetic particles in the range of 10Յd V Յ40 mm obtained by LA-ICP-MS and that by SEM is on the average 1.7 mm by using Al 2 O 3 calibration line and 2.4 mm by using MgO calibration line. 3) In this study, the LA-ICP-MS has been used for the determination of the inclusion composition and size distribution of oxide particles with d V Ͻ10 mm in an Fe-10mass%Ni alloy deoxidized by Al followed by Mg and Mg followed by Al addition.…”
Section: Introductionmentioning
confidence: 99%
“…Detailed explanation and some characteristics of LA-ICP-MS system are already given in previous article. 1,3) The standard samples and metal samples were ablated and analyzed by using the following parameters; laser scan rate of 0.01 mm/s, laser energy of 2.0 mJ/shot, frequency of laser shots of 20 Hz, defocus of laser beam of 0 mm, and integration time of 0.1 or 0.01 s. The width and depth of laser track on metal surface were on the average 25 and 50 mm, respectively at given ablation parameters. Total ablated area was 0.7 to 1.0 and 0.2 to 0.4 mm 2 for the samples in Exp.…”
Section: Sem and La-icp-ms Measurementmentioning
confidence: 99%
See 3 more Smart Citations