2015
DOI: 10.7567/jjap.54.07hc09
|View full text |Cite
|
Sign up to set email alerts
|

Quantitative measurement of high intensity focused ultrasound pressure field by optical phase contrast method applying non-continuous phase unwrapping algorithm

Abstract: A fast and accurate ultrasound pressure field measurement is necessary for the progress of ultrasound application in medicine. In general, a hydrophone is used to measure the ultrasound field, which takes a long measurement time and might disturb the ultrasound field. Hence, we proposed a new method categorized in an optical method called Phase Contrast method to overcome the drawback in the hydrophone method. The proposed method makes use of the spatial DC spectrum formed in the focal plane to measure the mod… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
13
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 12 publications
(13 citation statements)
references
References 27 publications
0
13
0
Order By: Relevance
“…The device consisted of a highintensity aerial ultrasonic sound source, [30][31][32] an LDV, a data logger, and a PC that controls the other instruments. To generate high-pressure [33][34][35] aerial ultrasonic waves, a pointconverged aerial ultrasonic sound source with a stripe-mode vibration plate (driving frequency: 28 kHz) was used. This sound source focused the acoustic waves to a point about 130 mm from the sound source opening.…”
Section: Experimental Apparatus and Measurement Methodsmentioning
confidence: 99%
“…The device consisted of a highintensity aerial ultrasonic sound source, [30][31][32] an LDV, a data logger, and a PC that controls the other instruments. To generate high-pressure [33][34][35] aerial ultrasonic waves, a pointconverged aerial ultrasonic sound source with a stripe-mode vibration plate (driving frequency: 28 kHz) was used. This sound source focused the acoustic waves to a point about 130 mm from the sound source opening.…”
Section: Experimental Apparatus and Measurement Methodsmentioning
confidence: 99%
“…This can be a disadvantage of the direct measurement of the entire field including the focal region unless we have a dependable phase unwrapping algorithm. 22) The steps in combination with acoustic holography to avoid the above-described problem were as follows.…”
Section: Acoustic Holographymentioning
confidence: 99%
“…Although optical measurement methods [14][15][16][17][18][19][20][21][22][23][24][25] are fast and have no risk of disturbing the field, such conventional methods are qualitative. [16][17][18] However, they can be improved to be quantitative enough to measure a 3D pressure field by combining them with a computed tomography (CT) algorithm 26) in a very short time.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Many methods were proposed for US-guided HIFU therapy. [7][8][9] In several studies, HIFU therapy was monitored by conventional B-mode US imaging. 10,11) B-mode imaging is well studied and its images can be obtained in real time.…”
Section: Introductionmentioning
confidence: 99%