2018
DOI: 10.1039/c7nj04998f
|View full text |Cite
|
Sign up to set email alerts
|

Quantum chemical and electrochemical studies of lysine modified carbon paste electrode surfaces for sensing dopamine

Abstract: We have improved the sensitivity of a carbon paste electrode from lysine for the sensitive detection of dopamine.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
13
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
9
1

Relationship

2
8

Authors

Journals

citations
Cited by 35 publications
(13 citation statements)
references
References 50 publications
0
13
0
Order By: Relevance
“…As a comparison, the voltammogram of the unmodified CPE shows a small broad peak, which is difficult to assign to a redox reaction associated with Cd(II) at the electrode surface. However, this small anodic peak provides evidence of the absence of a significant pre-concentration, and as a consequence limited diffusion of Cd(II) on the bare electrode, where the electron transfer will take place on the first layer of graphite [ 43 ]. On the other hand, the distinguished and remarkable enhancement of the oxidation peak of cadmium obtained with the modified electrode was due to the high surface area of the swollen PAA-co-IA/NaOH/B-MWCNT hydrogel, which possessed more active sites that could promote the adsorption and electron transfer between the electrode and analyte.…”
Section: Resultsmentioning
confidence: 99%
“…As a comparison, the voltammogram of the unmodified CPE shows a small broad peak, which is difficult to assign to a redox reaction associated with Cd(II) at the electrode surface. However, this small anodic peak provides evidence of the absence of a significant pre-concentration, and as a consequence limited diffusion of Cd(II) on the bare electrode, where the electron transfer will take place on the first layer of graphite [ 43 ]. On the other hand, the distinguished and remarkable enhancement of the oxidation peak of cadmium obtained with the modified electrode was due to the high surface area of the swollen PAA-co-IA/NaOH/B-MWCNT hydrogel, which possessed more active sites that could promote the adsorption and electron transfer between the electrode and analyte.…”
Section: Resultsmentioning
confidence: 99%
“…have already been reported. Modification of a sensing electrode is usually performed to improve the sensing properties of electrode [28][29][30][31][32][33][34][35].…”
Section: A D V a N C E D O N L I N E A R T I C L Ementioning
confidence: 99%
“…From curve b it is obvious that the oxidation peak current and oxidation peak potential responses were not revealed in the absence of IS (curve b) but under alike condition, in the presence of IS (curve a), an improved voltammetry response is observed. [28][29][30]…”
Section: Electrochemical Behaviour Of Is At Sdsmcntpementioning
confidence: 99%