2013
DOI: 10.1016/j.brachy.2012.03.006
|View full text |Cite
|
Sign up to set email alerts
|

Radiation oncology and medical physicists quality assurance in British Columbia Cancer Agency Provincial Prostate Brachytherapy Program

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
18
0

Year Published

2013
2013
2017
2017

Publication Types

Select...
9

Relationship

4
5

Authors

Journals

citations
Cited by 28 publications
(19 citation statements)
references
References 29 publications
1
18
0
Order By: Relevance
“…The PSA control curves only divide after 3 years of follow-up as the use of neoadjuvant hormone manipulation masks the impact of radiation dose on PSA control in the initial years. The British Colombia group provide an excellent example with a rigorous QA program and excellent implant quality across the province and multiple operators [13]. In over 2000 patients a median D90 of 150Gy is achieved with few low dose implants and excellent clinical outcomes.…”
Section: Discussionmentioning
confidence: 99%
“…The PSA control curves only divide after 3 years of follow-up as the use of neoadjuvant hormone manipulation masks the impact of radiation dose on PSA control in the initial years. The British Colombia group provide an excellent example with a rigorous QA program and excellent implant quality across the province and multiple operators [13]. In over 2000 patients a median D90 of 150Gy is achieved with few low dose implants and excellent clinical outcomes.…”
Section: Discussionmentioning
confidence: 99%
“…75 or D 90 ! 80% (14). For CTV dosimetry, there are no guidelines to stratify implant quality (6), and we used the same prostate metrics to stratify CTV to good, suboptimal, or poor implants.…”
Section: Ctv Dose Coveragementioning
confidence: 99%
“…1de1f). We used the British Columbia Cancer Agency criteria for evaluation of prostate dosimetry (14). Good prostate implants were defined as those having V 100 O 85% and D 90 O 90%, suboptimal implants were defined as those with V 100 of 75e85%, or D 90 80e90%, whereas poor implants were defined as those with V 100 !…”
Section: Ctv Dose Coveragementioning
confidence: 99%
“…As with radical prostatectomy, 44,45 it is critical for brachytherapists to maintain a minimum volume of cases annually to maintain their skill-set. 46 It takes about 1 year of fellowship training to practice independently with competence. Unlike with surgery, training is available in only a few centres in Canada.…”
Section: Discussionmentioning
confidence: 99%