The goal of this work is to develop a technique to measure the x-ray diffraction signals of breast biopsy specimens. A biomedical x-ray diffraction technology capable of measuring such signals may prove to be of diagnostic use to the medical field. Energy dispersive x-ray diffraction measurements coupled with a semianalytical model were used to extract the differential linear scattering coefficients [mus(x)] of breast tissues on absolute scales. The coefficients describe the probabilities of scatter events occuring per unit length of tissue per unit solid angle of detection. They are a function of the momentum transfer argument, x=sin(theta/2)/X, where theta=scatter angle and lambda=incident wavelength. The technique was validated by using a 3 mm diameter 50 kV polychromatic x-ray beam incident on a 5 mm diameter 5 mm thick sample of water. Water was used because good x-ray diffraction data are available in the literature. The scatter profiles from 6 degrees to 15 degrees in increments of 1 degrees were measured with a 3 mm x 3 mm x 2 mm thick cadmium zinc telluride detector. A 2 mm diameter Pb aperture was placed on top of the detector. The target to detector distance was 29 cm and the duration of each measurement was 10 min. Ensemble averages of the results compare well with the gold standard data of A. H. Narten ["X-ray diffraction data on liquid water in the temperature range 4 degrees C-200 degrees C," ORNL Report No. 4578 (1970)]. An average 7.68% difference for which most of the discrepancies can be attributed to the background noise at low angles was obtained. The preliminary measurements of breast tissue are also encouraging.
A CdZnTe detector (CZTD) can be very useful for measuring diagnostic x-ray spectra. The semiconductor detector does, however, exhibit poor hole transport properties and fluorescence generation upon atomic de-excitations. This article describes an analytic model to characterize these two phenomena that occur when a CZTD is exposed to diagnostic x rays. The analytical detector response functions compare well with those obtained via Monte Carlo calculations. The response functions were applied to 50, 80, and 110 kV x-ray spectra. Two 50 kV spectra were measured; one with no filtration and the other with 1.35 mm Al filtration. The unfiltered spectrum was numerically filtered with 1.35 mm of Al in order to see whether the recovered spectrum resembled the filtered spectrum actually measured. A deviation curve was obtained by subtracting one curve from the other on an energy bin by bin basis. The deviation pattern fluctuated around the zero line when corrections were applied to both spectra. Significant deviations from zero towards the lower energies were observed when the uncorrected spectra were used. Beside visual observations, the exposure obtained using the numerically attenuated unfiltered beam was compared to the exposure calculated with the actual filtered beam. The percent differences were 0.8% when corrections were applied and 25% for no corrections. The model can be used to correct diagnostic x-ray spectra measured with a CdZnTe detector.
PurposeTo analyze the seed loss and displacement and their dosimetric impact in prostate low-dose-rate (LDR) brachytherapy while utilizing the combination of loose and stranded seeds.Material and methodsTwo hundred and seventeen prostate cancer patients have been treated with LDR brachytherapy. Loose seeds were implanted in the prostate center and stranded seeds in the periphery of the gland. Patients were imaged with transrectal ultrasound before implant and with computerized tomography/magnetic resonance imaging (CT/MR) one month after implant. The seed loss and displacement had been analyzed. Their impact on prostate dosimetry had been examined. The seed distribution beyond the prostate inferior boundary had been studied.ResultsThe mean number of seeds per patient that were lost to lung, pelvis/abdomen, urine, or unknown destinations was 0.21, 0.13, 0.03, and 0.29, respectively. Overall, 40.1% of patients had seed loss. Seed migration to lung and pelvis/abdomen occurred in 15.5% and 10.5% of the patients, respectively. Documented seed loss to urine was found in 3% of the patients while 20% of patients had seed loss to unknown destinations. Prostate length difference between pre-plan and post-implant images was within 6 mm in more than 98% of cases. The difference in number of seeds inferior to prostate between pre-plan and post-implant dosimetry was within 7 seeds for 93% of patients. At time of implant, 98% of seeds, inferior to prostate, were within 5 mm and 100% within 15 mm, and in one month post-implant 83% within 9 mm and 96.3% within 15 mm. Prostate post-implant V100, D90, and rectal wall RV100 for patients without seed loss were 94.6%, 113.9%, and 0.98 cm3, respectively, as compared to 95.0%, 114.8%, and 0.95 cm3 for the group with seed loss.ConclusionsSeed loss and displacement have been observed to be frequent. No correlation between seed loss and displacement and post-plan dosimetry has been reported.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.